Technical Data
Type
Rated voltage
Chain type
Nominal pressure
Nominal locking force
Service life
Housing
Protective system
Temp.range
Fire stability
Stroke lenght *
Additional functions: *
* Programmable with software SCS
Running speed and forces
All forces + approx. 20 % switch-off reserve (temporary)
Closing edge protection
In the "CLOSE" direction the drive has an active
protection for the main closing edge. If there is an
overload in the closing ranges 3 and 2, the drive runs
"OPEN" for 10 seconds, then "CLOSE" again. If
closing is not possible after three attempts, the drive
remains in this position.
In addition, the drive is equipped with passive
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing
edges. Danger of crushing hands and
fingers!
99.823.67 2.5/11/13
CDC 200/350 -BSY+
24 V DC, ±15 %, 0,6 A
Standard chain
200 N
approx. 1500 N
>10.000 double strokes
Aluminium die casting
IP 50
-5 ... +75 °C
30 min / 300 °C
max. 350 mm
Closing edge protection = activated (3 repetitions of stroke)
Locking relief = activated (retraction lift max. 0,2 mm)
English
CDC 200/350 -SBD -BSY+
24 V DC, ±15 %, 0,5 A
Side bow chain
150 N
Beside
closing edge
CDC 200/350 (-SBD)-BSY+
7/20