When transporting the com-
pressor in a vehicle, trailer,
etc. ensure that the air tank is
drained and the unit is secured
and placed on a flat horizon-
tal surface. notE: Use rec-
ommended tie down points
(Q) when transporting. Use
care when driving so to avoid tipping the unit over in the vehicle.
Damage can occur to the unit or surrounding items if unit is tipped.
Use a ramp if loading or unloading the unit from a height of more
than 1" (30.5 cm).
lIftInG
Always use two people when lifting and lift from the recommended
lift points (P).
WARNING: Risk injury from lifting. Unit weighs more than 160 lbs.
(72.6 kg) Do not move or lift without assistance.
MoVInG
1. Grasp handle (O) of compressor, and lift compressor high
enough so unit can be rolled on the front tire(s).
WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when rolling compressor so that unit does not tip or
cause loss of balance.
. When location is reached slowly lower rear of compressor to
ground. Always store compressor in a horizontal position.
PrEPArAtIon For uSE
Pre-Start Checklist (Fig. 1)
1. Ensure the On/Off switch (C) is in the OFF position.
. Plug the power cord into the correct branch circuit receptacle. See
Voltage and Circuit Protection under Installation.
Q,P
Q,P
O
Q
3. Ensure air tank is drained, see draining Air tank under
Maintenance.
4. Ensure the drain valve (J) is closed.
5. Ensure safety valve (I) is functioning properly, see Checking
safety Valve under Maintenance.
6. Check pump oil level, see Compressor Pump oil under
Maintenance.
CAUTION: Do not operate without oil or with inadequate oil. EMGLO
is not responsible for compressor failure caused by inadequate oil.
7. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
8. Visually inspect drive belt. Replace belt if frayed, cracked, or worn.
notE: Outer belt cover must be removed to inspect drive belt.
9. Visually inspect air hose, replace if needed.
10. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
WARNING: Risk of Bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer's maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
11. Ensure all covers and labels are in place, legible (for labels) and
securely mounted. Do not use compressor until all items have
been verified.
Initial Set-up (Fig. 1)
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
1