Maintenance Chart - Emglo K15A-8P Manual De Instrucciones

Compresor de aire eléctrico portátil con ruedas para contratistas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

. Turn regulator knob (F) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 PSI (0 kPa).
3. Remove hose and accessory.
4. Drain the air tank, see draining Air tank under Maintenance.
Ensure air tank pressure gauge reads 0 PSI (0 kPa).
WARNING: Risk of bursting. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk
of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAIntEnAnCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure On/Off switch is in the OFF position.
. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
notE: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
notE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
notE: Any service operations not included in this section should be
performed by an EmGLO factory service center or an EmGLO autho-
rized service center.

Maintenance Chart

Procedure
Check safety valve
Inspect air filter +
Drain air tank***
Check pump oil level
Change pump oil** +
Oil leak inspection
Inspect drive belt
Check drive belt tension
Check pulley/flywheel
alignment
Check for unusual noise/
vibration
Check for air leaks*
Clean compressor exterior
* To check for air leaks apply a solution of soapy water around joints.
While compressor is pumping to pressure and after pressure cuts out,
look for air bubbles to form.
** The pump oil must be changed after the first 0 hours of operation.
EMGLO
Thereafter, when using
oil every 00 hours of operation or once a year, whichever comes first.
*** Drain tanks daily or after four hours of use.
+ Perform more frequent in dusty or humid conditions.
14
daily
Weekly Monthly
1 year or
200 Hours
X
X
X
X
X
X
X
X
X
X
Synthetic Blue compressor oil, change
X
X

Publicidad

Tabla de contenido
loading