Compare the illustrations with your generator to familiarize yourself with the locations of various controls and product warnings .
Engine Switch
120 Volt AC, 20 Amp, GFCI Duplex Receptacles — Used
to supply 120 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads .
120/240 Volt AC, 30 Amp Locking Receptacle — Used to
supply 120 / 240 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads .
Circuit Breakers (5750 Watt ONLY) — The 120 Volt AC,
20A GFCI duplex receptacles are provided with "push to
reset" 20 Amp circuit breakers to protect the generator
against electrical overload .
Low Oil
Shutdown
CO Detection™
Carbon Monoxide
(CO) Shutdown
Indicator Light
Circuit Breakers
120/240 Volt AC, 30
Amp Locking Receptacle
120 Volt AC, 20 Amp
GFCI Duplex Receptacles
CO Detection Carbon Monoxide (CO) Shutdown Indicator
Light — Indicates the engine shutdown due to carbon
monoxide accumulation around the generator or a CO
Detection system fault occurred .
Low Oil Shutdown — This unit is equipped with a low oil
protection device . Oil must be at proper level for engine
to run . If the engine oil drops below a preset level, an oil
switch will stop the engine . Check oil level with dipstick .
Main Breaker — Protects generator against electrical
overload . If breaker trips, it cuts power to all receptacles .
Engine Switch — Set this switch to ON (I) before starting
engine . Set switch to OFF (0) to shut off engine .
Features and Controls
Main Breaker
5