Measuring fundamentals
The infrared thermometer enables you to measure surface temperatu-
res contactlessly in the range from -50°C to +350°C. You can
safely measure hot surfaces or hazardous substances. It is ideal
for establishing thermal bridges when renovating old buildings and
for measuring inaccessible positions. The measuring instrument
shows the temperature in degrees Celsius or Fahrenheit.
Application
Switch on the instrument by pressing the measuring key (2).
CAUTION! Automatic switch-off. The instrument will switch itself off automatically after 10 seconds has passed without pressing a key.
Press the on-off laser pointer key (5), in order to activate the laser targeting aid. The
the laser pointer aid is switched on. Please note that the laser pointer only represents a targeting aid. The measurement will be
carried out with an infrared signal. The infrared signal cannot measure through glass, although the laser pointer can be projected
through it. The instrument will measure the surface temperature of the glass pane in this case.
Point the thermal measuring instrument at the surface to be measured and press the measuring key (2). The surface temperature
will be shown on the display (3). Press the switch-over key (4), in order to switch over the display between degrees Celsius and
Fahrenheit. The measured result will be shown on the display for 5 seconds. A permanent measurement will be carried out if you
keep the measuring key pressed (2).
The measuring instrument has optics at the ratio of 12:1. This means that the measuring point has a diameter of 1 m (Fig. 1) at
a distance of 12 metres. The surface to be measured should be at least twice as large as the measured point, in order to receive
accurately measured results.
You can switch the display´s lighting on and off with the display lighting key (3). The display lighting enables you to work in bad
lighting conditions.
kwb_ThermoFixx_Bedienungsanleitung.indd 5
1) Laser beam outlet
1)
2) Measuring key
3) LCD display
4) Switch-over key between °C and °F.
2)
5) On-off laser pointer
6) On-off display lighting
7) Battery compartment
7)
Instructions for use
AUTO-OFF
10 s
12 m
12 : 1
symbol will appear on the display (3) when
0,5 s
– 50°C
+ 350°C
1 m
01.04.15 11:44