Descargar Imprimir esta página

General Information - Pahlen Aqua compact Manuiale D'uSa

Ocultar thumbs Ver también para Aqua compact:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
Electric heater Aqua compact
Start
1. Fill water into the pool up to the right level.
2. Start the pump for the pool water circulation.
3. Make sure that water circulates normally in the system before the power to the heater is turned on. The heater will start only
when the system is emptied of all air.
4. The heater functional test:
Turn the thermostat knob back and forth and check that the thermostat switch is turning on and off.
The flow monitor is checked by switching off the flow through the heater with a shut-off valve, and check that the contactor is
switching off.
5. Set the desired pool temperature by turning the knob to the desired temperature.
6. The heater shall now heat the pool water to the desired temperature.
Operation
When flushing and cleaning the filter, turn off the heater power. In case of freezing, switch off the power and drain the heater of
all water.

General information

Ensure good operation and long life of the electric heater by following water quality limit values below.
Chlorine content:
max 3,5 mg/l (ppm)*
pH value:
7,2 - 7,6
Alkalinity:
60-120 mg/l (ppm)
Calcium hardness:
100-300 mg/l (ppm)
Iron:
max 0,1 mg/l (ppm)*
Copper:
max 0,2 mg/l (ppm)*
Manganese:
max 0,05 mg/l (ppm)*
Phosphorus:
max 0,01 mg/l (ppm)*
Nitrate:
max 50 mg/l (ppm)*
Incoloy
Chloride (salt) content: max 250 mg/l (ppm)
Titanium
Chloride (salt) content: max 35 000 mg/l (ppm)
If water quality limit values are not met, the product warranty is not valid.
Troubleshooting
1. Check the fuses.
2. The overheating protection may have tripped:
Find the cause. After the cause has been found and corrected, the overheating protection must be reset
- Remove protective cover, see Fig. 1 below.
- Press the reset button on the junction box, see Fig. 2 below.
- Replace protective cover.
3. Check that the flow monitor is preset at a minimum flow rate of 90 l/min.
4. Set the thermostat to a higher temperature.
* according to EN 16713-3
A ( 1 : 1 )
Protection cap
Cap
1
A
Surface treatment
E
The tolerance class in accordance with this
part of ISO 2768-1
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
9
A ( 1 : 1 )
2
A
Designed by:
Drawn by: Date
Approved by:
TS
2012-06-21
Assembly drawing no.
Art.no.
Surface treatment
E
Scale
Revised by: Date
Demontering lock
The tolerance class in accordance with this
part of ISO 2768-1
överhettningsskydd
Drawing number
Rev.no.
M11668 0
Demontering lock
överhettningsskydd
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
ENGLISH
Protection cap
Cap
Reset button
Reset button
Designed by:
Drawn by: Date
Approved by:
TS
2012-06-21
Assembly drawing no.
Art.no.
Scale
Revised by: Date
Drawing number
Rev.no.
M11668 0

Publicidad

loading

Este manual también es adecuado para:

141600141601141602141603141604141605