noise exceeds the adjustment carried out. Under no circumstances
should the music exceed this Level.
Check the adjustments carried out by using the Bypass selector (pressing
keys
and
onsets. Check the indicator Led for the Bypass situation.
IMPORTANT: all the adjust procedures described here must be done
with Pink Noise as sound source. This signal provides a reference over
all the audible spectrum with the same sound pressure level.
Now, connect the Sound Source and check the results by playing the actual
musical program. Check the Accuracy of the TSL Control in its response to
the presence of the Peaks considered normal in Musical Dynamics. There
should be overall Control. Place all the Level Controls of the Mixer at their
maximum gain and check that the Sound-meter has not registered any
appreciable increase.
Very Important Advice for the Technician Installation Responsible:
It is not necessary, under any circumstances, to carry out the Adjustment
Tests by placing the Mixer Control (Gain, Tones and Volume) to maximum
power. If this is done, the only result obtained is a new physical element, the
distortion of the Mixer itself, which greatly hampers the normal accurate
procedure of the Adjustments and Measurements.
Once the system has been well calibrated, starting from the Levels and the
disposition of the control at their normal state (maximum 0 dB), it will be
totally impossible to exceed the adjustments carried out, while the maximum
fidelity of the musical program will be respected at all times. This fact can be
perfectly demonstrated once as the corresponding Adjustments have been
finished.
4 - PENALIZATIONS
• SLO: (Sound Level Optimizer) SENSOR MICROPHONE. Its disconnection will
automatically interrupt the general signal. The "input-output" comparison device
will not allow the Sensor Microphone to be blocked. on detecting an "abnormal"
difference in level, it will interrupt the general signal. Any environmental noise
generated by the Sound equipment itself or by any other separate Sound
source -environmental murmuring- surpassing the Limits set in the SLO will
cause the general and proportional attenuation of the Equipment's working
Level or its INTERRUPTION if the excess sound is produced repeatedly and at
a level much higher than the level authorized. Occasional whistling or shouting
will cause an immediate proportional attenuation, but not a penalization.
• SIGNAL EXCESS: The TSL foresees a single situation of "punishment", once
the Limitation circuits have been activated (Orange Limiter active led on),
whenever there is a continuous and repeated detection of Signal Excess
during 3 seconds, led BYPASS on). Re-adjust any
37