Table of contents
1.0
2.0
3.0
Safety ....................................................... 3
4.0
Installation ............................................... 6
5.0
Daily Use ................................................ 12
6.0
Maintenance ........................................... 13
7.0
Servicing ................................................ 14
8.0
9.0
Recycling ................................................ 17
10.0 Warranty ................................................ 17
On all our products there is a label
Product:
Jøtul
indicating the serial number and
Room heater fired by solid fuel
year. Write this number in the
Standard
:
Minimum distance to adjacent combustible materials:
Minimum distance to adjacent combustible materials:
place indicated in the installation
Emission of CO in combustion products
:
Flue gas temperature
:
Nominal heat output
:
instructions.
Efficiency
:
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number
Country
Classification
Certificate/
Approved by
standard
when contacting your retailer or
Norway
Klasse II
SP Sveriges Provnings- och
SP
Sweden
OGC
Forskningsinstitut AB
Jøtul.
SP Swedish National
Testing and Research
EUR
Intermittent
EN
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
1.0 Relationship to the
authorities
•
Installation of a fireplace must be carried out in compliance
with national laws and regulations. All local ordinances,
including those that refer to national and European
standards, must be complied with when products are
installed.
•
The installation can only be put into use after it has been
checked by a qualified inspector.
•
Contact your local building authorities before installing a
new fireplace.
2.0 Technical data
Material:
Finish:
Smoke outlet:
Flue pipe dimension:
Outside air connection:
Product weight:
Burn chamber with long legs:
Burn chamber with base:
Soapstone top:
Optional extras
Product dimensions, distances: See Fig. 1
Technical data in acc. with EN 13240
Nominal heat output:
Flue gas volume:
Chimney draught, EN 13240:
Recommended negative pressure
in smoke outlet:
Efficiency:
CO emissions (13% O 2 ):
CO emissions (13% O 2 ):
NOx at 13% O 2 :
OGC @ 13 % O 2 :
Particle emission NS 3059:
Air consumption:
Chimney temperature, EN 13240:
Temperature in smoke outlet:
Dust:
Type of fuel:
Max. log length:
Fuel consumption:
Max. kindling amount:
Nominal kindling amount:
Operation:
Intermittent combustion here means normal use of a fireplace,
i.e. add more fuel as soon as the fire has burned down to
embers.
ENGLISH
Cast iron
Black paint / enamel
Top, rear
Ø 150 mm
Alu. flex - Ø 80 / Ø 100 mm
143 kg
169 kg
36 kg
Floorplates, Ash lip, kit for
outside air connection,
protection grid for sweep
ball, short legs, soapstone
top, short legs
7 kW
7.1 g/s
12 Pa
14-16 Pa
79%@7.5 kW
0.06%
786 mg / Nm 3
85 mg / Nm 3
64 mg/Nm 3
1.5 g / kg
6,1 litre/sec or 22 m 3 /h
261 o C
313 o C
<7 mg/Nm 3 @13%O 2
Wood
41 cm
2.25 kg/h
2.4 kg
1.8 kg
Intermittent
3