GB
1. Press the ECON switch to the OFF position.
2. Connecting the battery charging cable.
a) Connect the battery charging cable to the battery
b) Plug the charging wires into the DC outlet of the generator.
WARNING!
- The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequa-
te ventilation when charging or using batteries.
- Battery posts, terminals, and related accessories contain lead components. Wash hands after
handling.
c) Connect the positive (red) terminal of the charging wire to the positive (+) battery terminal and negative
(black) terminal of the charging wire to the negative (-) battery terminal.
3. Press the start switch to RUN position.
4. Press the DC breaker switch to ON position
(Refer to Fig. 4.12 for CI 1000 and Fig. 4.13 for CI 2000 / CI 3000)
5. Start the generator.
4.3: Stopping the generator set
for CI 1000/CI 2000 CI 3000 (AC Operation)
1. Turn off the device and unplug devices from the generator receptacles.
2. Press the start switch to the STOP position.
3. Rotate the fuel switch to the OFF position (in the clockwise direction)
NOTICE:
Be sure the fuel SWITCH is in the OFF position and the start switch is in the STOP position when stopping,
transporting and/or storing the generator.
For CI 1000/CI 2000 CI 3000 (DC Operation only)
NOTICE:
An overloaded DC circuit, excessive current draw by the battery, or a wiring problem will automatically trip (turn
off) the DC breaker switch. If this happens, wait a few minutes before pressing the breaker switch to the ON
position to resume operation. If the breaker switch continues to go OFF, discontinue charging and contact your
authorized dealer.
Disconnecting the charging wire
1. Stop the engine.
2. Disconnect the negative (black) terminal of charging wire from the negative (-) battery terminal.
3. Disconnect the positive (red) terminal of the charging wire from the positive (+) battery terminal.
4. Disconnect the charging wire from the DC receptacle of the generator.
62