• EPL-Transmitter/RC
The inscription of the rotary knob on EPL-Transmitter/RC differs as follows:
Main group "g" left rotary knob
EPL modules
A
B
C
D
GB
E
F
G
H
I
J
K
L
M
N
O
P
4.2 Extension of an Existing Domain
• Connect the new EPL modules according to Point 3 and set the groups at the rotary
knobs as described under Point 4.1.
• Switch on the mains voltage.
• The Conf. LED flashes on all new modules. This means that the EPL modules are not
configured/programmed (default setting) (fig. 1).
• Use a screwdriver to briefly press the Prog. button on any already programmed EPL
module in the domain which is being extended.
• The EPL module transmits the existing domain coding. All unconfigured EPL modules
in range will program themselves automatically to this domain.
• The modules are programmed and ready for operation after 5 s - 10 s.
All Conf. LEDs stop flashing.
• If one EPL module's Conf. LED continues to flash, follow the practical advice under Point 5.