Self Test And Diagnostic Sequences - Dedicated Micros drx 300-II Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4. Self-test and Diagnostic Sequences
The diagnostic system and status check, which will activate each camera function for two seconds
in turn, is activated either locally by pressing a switch on the PCB or remotely from a keypad. When
testing the system locally, before initiating the diagnostic system and status check by turning SW8
ON momentarily, ensure that the Cable LED is on (i.e. either flashing or continuously). If not, this
indicates that either the power is not attached to the PCB, or there has been a major PCB error.
Rectify accordingly.
The Error LED flashes at a two-second rate during self-test. If the Cable LED fails to extinguish,
then the unit is unable to self-tune and should be returned for repair.
Order of function test: Camera Moves Left
drx 300-II Installation Manual
Camera Moves Right
Camera Moves Up
Camera Moves Down
Auxiliary Function
Lens Zoom-In
Lens Zoom-Out
Lens Focus Near
Lens Focus Far
Auto Iris Open
Auto Iris Close
Diagnostic Check Complete, unit resets and continues normal operation
Page. 7

Publicidad

Tabla de contenido
loading

Tabla de contenido