Simu T5E-SP Traducción Del Manual Original página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
These instructions apply to all T5E-SP/T6E-SP drive, the different versions of which are available in the current catalogue.
Field: The T5E-SP/T6E-SP drive are designed to drive all types of outdoor awnings with cassette . The installer, who must be a
motorisation and home automation professional, must ensure that the drive product is installed in accordance with the standards
in force in the country in which it is installed such as EN 13561 relating to outdoor screens and awnings.
Liability: Before installing and using the drive, please read operating and installation guide carefully. Please read these
instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the instruc-
tions detailed in the attached Safety instructions document must also be observed. The drive must be installed by a motorisation
and home automation professional, according to instructions from Simu and the regulations applicable in the country in which it is
commissioned. It is prohibited to use the drive outside the field of application described above. Such use, and any failure to com-
ply with the instructions given in this guide and in the attached Safety instructions document, absolves Simu of any liability and
invalidates the warranty. The installer must inform its customers of the operating and maintenance conditions for the drive and must
provide them with the instructions for use and maintenance, and the attached Safety instructions document, after installing the
drive. Any After-Sales Service operation on the drive must be performed by a motorisation and home automation professional. If
in doubt when installing the drive, or to obtain additional information, contact a Simu adviser or go to the website www.simu.com.
1
Installation
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC 60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- T5E-SP: The cable for the motor can be removed. If it is damaged, replace by the same. The cable may only be connected
to the motor by qualified personnel. The connector is to be assembled without damaging the contacts. The continuity of the
earth connection must be ensured.
- T6E-SP: The cable for the motor cannot be removed. If it is damaged, return the drive to the After-Sales department.
Drilling of the tube:
C
D
55
22,8
48*
4
96
27,5
ø9
ø64
7,45
Assembly:
1
T5E-SP/T6E-SP
(230V~50HZ)
A
4xØB / 90°
L1
IP44
L2
L1
IP44
L2
5
9910004
2
3
Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - FRANCE
Ø min.
/
/
47
/
/
47
/
/
/
60
/
/
Ø4,8 x 10
STEEL
Ø5 x 10
4
EN- ORGINAL INSTRUCTIONS
5013731G
SIMU S.A.S. au capital de 5 000 000 €
RCS VESOUL B 425 650 090 - SIRET 425 650 090 00011
n° T.V.A CEE FR 87 425 650 090
A
ØB
C
585
5
26
659
5
26
716
5
36
i
-20°C / +60°C
mm
D
L1
L2
4,2
598 621
4,2
672 695
8
729 758
1/3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T6e-sp

Tabla de contenido