Simu T5E-SP Traducción Del Manual Original página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
3
Final wiring
- Be careful of the direction of rotation (§2.2).
- Mandatory use of a reversing switch that stops the ▲ and ▼ keys being activated simultaneously.
- Possibility of wiring 3 motors max. in parallel on one switch.
- The length of the cable between the electrical switch and the motor must not exceed 50 m.
- Please do contact SIMU when using KNX / EIB electronic switching control devices.
- Attach cables to prevent any contact with moving parts. If the motor is used outdoors and if the power supply cable is
of the H05-VVF type, then run the cable in a UV-resistant conduit, e.g. trunking.
Blue
Brown
Black
Green/yellow
4
Re-adjustment of down end limit
- With the T5E-SP / T6E-SP motor, there is no manual adjustment for the upper end limit.
b
a
a. Position the motor on the down end limit set in §2.5 using the key ▼.
b. Press the ▼ key 6 times, each time for 6 seconds. After the 2nd, 3rd, 4th, 5th, and 6th press the motor rotates briefly one way, then
the other*.
c. Position the motor on the new desired lower position using the ▲ and ▼ keys.
d. To confirm the new end limit position, press ▲ twice, once for half a second without the motor rotating and the second time for at least
3 seconds, so the motor rotates briefly one way, then the other*.
5
Cancelling of end limit adjustments
- Connect the motor to the settings switch (§2.1)
- Press the ▲ and ▼ keys simultaneously, for at least 7 seconds. The motor rotates
one way, then the other, then a few seconds later rotates in both directions.
After this operation, the motor returns to its factory settings, repeat the
operations from chapter 2.
6
Operation and maintenance
- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
Tips and recommendations for use:
PROBLEMS
The motorised product does not operate. The overheating protection on the drive has been activated.
If the motorised product still does not work, contact a drive and home automation professional.
SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and
used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular
of the Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU. The full text of the EU declaration of conformity is available at www.simu.com..
Emmanuel CARMIER, general director, GRAY, 10/2016.
N
L
PE
>>
>>
>>
>>
>>
POSSIBLE CAUSES
T5E-SP/T6E-SP
d
c
0,5s
>>
>7s
2s
7s
SOLUTIONS
Wait for the drive to cool down.
+
6s max.
>3s
>>
3/3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T6e-sp

Tabla de contenido