Technical data for the inputs (contact input, level input)
Data
Voltage with open contacts
Input resistance
Short circuit current
Maximum level for "0" signal
Maximum level for "1" signal
Minimum closing time of contact input
Reaction time level input
Temperatures
CAUTION!
The 240 stroke version may fail
The 240 stroke version can overheat at ambient temperatures higher than 35 ℃.
–
Only use the 240 stroke version at ambient temperatures of less than 35 ℃.
Data
Storage and transport temperature
Ambient temperature during operation
Maximum permissible medium temperature
Dosing head material
Polypropylene
Clear acrylic
PVDF
Long term
at maximum back pressure
50 °C
45 °C
60 °C
Technical data
Value Unit
5 ± 0.5 VDC
12 ± 0.5 ㏀
0.5 ± 0.05 mA
1.0 V
3.5 V
20 ms
2 s
Value Unit
-10 ... +50 °C
-10 ... +45 °C
For max. 15 min
at max. 2 bar
100 °C
45 °C
120 °C