Install Pre-Filters; Install Ro Membrane Element - Genpar NURFILTER Blue Tide Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Install Pre-Filters

• Remove Pre-Filters from packaging
• Place Filters in appropiate housings according to labels and install filter housing from right to left in the following
order: PP, GAC, CTO.
• Tigthening housings with wrench provided.
leaking.
Note: When installing housings make sure housing level and even to avoid leaking

Install RO Membrane Element

NOTE: Before proceeding with membrane element installation, please flush pre filters thoroughly.
(Instructions on how to perform filter flush provided in next section).
Housing Connection
Pure water outlet
• Remove RO housing cap using wrench.
• Remove RO element from packaging.
• Insert RO element into housing with the small double O rings facing inward.
• Install Membrane housing cap and tighten with wrench provided.
8
+1-503-GENPAR-6 - www.mygenpar.com
Note: When installing housings make sure housing level and even to avoid
O Rings
Drain Water Outlet
Membrane housing
Genpar Industries LLC USA
RO Membrane
Water Inlet
Seal Ring