Dual voltage models
Ckeck voltage at mains (110 or 230V ~ 50Hz)
To change voltage remove two fixing screws, move selector to desired voltage, reverse switch plate and
screw back.
Automatic ignition models
Turn the fan switch to position II (for heating) and make sure that the fan is turning. After a brief
preventilation the flame ignites.
Regulate the gas flow pressure according to the thermal power desired, by turning the wheel of the
pressure reducer anticlockwise to increase the pressure or clockwise to decrease.
If the flame ignites but after few seconds the heater locks, the RESET control lamp lights up. In this case
check that all the prescriptions of the previous paragraph about installation have been observed.Wait one
minute , then unlock the heater by pressing the RESET button and repeat the starting operations.
Contact your supplier should any problem continue.
CAUTION
If ignition is difficult or irregular before repeating the ignition operations make sure that the
fan is not locked and that air inlet and outlet are unobstructed.
3.2 SWITCHING OFF
To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts down and then turn
the fan switch to position O.
3.3 AIR CONDITIONING
The heater can also be used as a ventilator.
In this case remove the gas supply hose and connect the plug of the heater to a suitable electrical supply.
Set the fan switch to position I.
4. MAINTENANCE
The repairs or maintenance operations must only be carried out by qualified personnel.
The unit must be checked by a qualified technician at least once a year.
Regularly check the conditions of gas hose, and gas regulator if it must be replaced only use original spare
parts.
Before starting any maintenance operation on the heater disconnect from both gas and electrical supplies.
If the unit has not been used for a long period we advise that a technician carries out a general check up
before using. It is important to control the following:
Periodically check the gas supply hose conditions and,
should it be changed, use only original spare parts.
Check the starting electrode position (see Fig. 6).
Check the connections of the safety thermostat and of
the thermocouple: they must always be clean.
If necessary clean the fan blade and the inside of the
heater using compressed air.