Broan 345SOBK Manual Del Usuario página 2

Ventilador solar para ático de montaje en el techo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
Note: This ventilator is capable of replacing an existing
120 volt powered attic ventilator. Only a qualified per-
son should remove any electrical wiring in accordance
with local codes and standards.
1. Determine the sun's best exposure location on your roof
barring shade (trees, other buildings etc.) at 4:00pm in
the hottest month of the year. Generally, we recommend
a point located 24" – 36" on center below the roof peak
and centrally along the ridgeline on the south, southwest,
or west side of the home.
2. Prior to installation, we recommend setting up the
ventilator to verify operation. Take the ventilator to a
location exposed to sun. Removing the cardboard
cover from the solar panel should cause the ventilator
to operate. Secure cardboard in place over solar panel
(for safety).
MODELS 345SOBK • 345SOWW
3. Separate the dome from the base by removing four (4)
sheet metal screws. Set dome aside.
1
2
3
4
4. Working from the inside of your attic, find the desired
ventilator location and mark a spot halfway between
rafters at a point that is 24" – 36" below the roof ridge.
5. Drill a guide hole through the roof at this mark.
9
5
6
7
8
Page 2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

345soww

Tabla de contenido