H O W TO U S E

EMPTYING COLLECTED WATER

Remove bucket
Take the bucket out with both hands, while
1
grasping handles in left/right side of the bucket.
Remove the bucket cover.
When the bucket is full, it weighs about
12.5lb(5.7kg), so remove carefully.
Bucket Handle
Pour the water down the drain.
Carry the bucket by grasping bucket handle.
2
After emptying the bucket, wipe water inside.
If water remains in Float, "AUTO SHUT-OFF"
Switch will not operate properly, when bucket is
full. Wipe completely.
18
All manuals and user guides at all-guides.com
Bucket Handle
Bucket Handle
Replace the bucket.
• Make sure that the slots on the cover of bucket
3
are positioned correctly.
• Push the bucket securely with both hands. If
the bucket is not in the proper position, FULL
Sensor will activate and the dehumidifier will
not operate.
CAUTION
Bucket Handle
After stopping the unit, do not take out the
• •
bucket immediately.
The water remaining in the coils may fall to
the inside of the unit. (Wipe dripped water
with soft cloth.)
After taking the bucket out, do not touch any
• •
parts inside the unit.
The Sensor that detects Water FULL may not
function well.
Rinse the inside of the water bucket
• •
periodically (once a week). If you do not clean
for a prolonged time, the bucket may become
blackened.
Drain elbow should be cleaned every six
• •
months. Using cotton stick. When drain
elbow clogging is removed, water remained in
the unit will come out, so prepare dishes and
towels.
At a low temperature, frost builds up on the
• •
coils, so the amount of water in the bucket
diminishes. This is normal.
Drain