Step 7: Test Adjustment - Thermador P24GE Instrucciones De Instalación

Ocultar thumbs Ver también para P24GE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CAUTION
Thermador recommends that
burner adjustments be made by a
qualified technician at the time of
installation. Extreme care should
be used when adjustments are
made after installation. Improper
or lack of adjustments may create
harmful by products and may void
your warranty.
Fig. 13 - Proper Flame
(Approx.)
Top
Burners
1 to 1
/
"
-1
2
Step 7: Test and Adjustment
Install any loose components, such as burner caps and grates, that
may have been removed earlier. Before testing operation of the
appliance, verify that the unit and the gas supply have been carefully
checked for leaks and that the unit has been connected to the electric
power supply. Turn the manual gas shut-off valve to the open position.
Check operation of the sealed gas burners, griddle and grill by pushing
and turning each knob counterclockwise to HI. Check that the burner
caps are correctly seated on the burner bases. The burner igniters
will click until the flame ignites. The two far left sealed burners feature
®
XLO
, causing the flame to cycle on and off when the knob is set to
the XLO range. This is normal operation.
EACH GAS BURNER MUST BE EVALUATED FOR CORRECT
FLAME PERFORMANCE IMMEDIATELY AFTER INSTALLATION
OF THIS APPLIANCE. In PC Cooktop models, air shutter for the
grill burner (NOT top burners) is preadjusted at the factory. However,
environmental or installation conditions may require readjustments.
Grill
Flame evaluation is performed with burner's control knob at highest
setting.
/
to 1"
1
2
If the PLPKIT is used to convert this appliance from Natural to
Propane Gas, flame evaluation and air shutter readjustments must
be performed — see instructions provided with the PLPKIT for correct
recommendations.
Burner flames should be blue and stable with no yellow tips, excessive
noise, or lifting of the flame from the burner. If any of these conditions
exist, check that the air shutter (grill only) or burner ports are not
blocked or clogged. Remove any blockages that exist.
If the flame is too yellow, indicating insufficient air, adjust the shutter
more open to increase air inlet (grill only).
The sealed top burner flames should be approximately 1 to 1-1/2"
high. The grill burner flame should be 1/2" to 1". (See Fig. 13).
NOTE: No air shutter or low flame adjustment is necessary or possible
with the sealed top burners.
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

P24wkPc304Pc36Pc48

Tabla de contenido