The performance of these refrigerated cabinets was determined through tests conducted in compli-
ance with the standard
EN ISO 23953 - IEC/EN 60335-2-89 at the environmental conditions of the climatic class 3 (25 °C ,
60% R.H.) with safety test at 32°C +/-2°C see table:
Climatic Class of the
testing chamber
0
1
2
3
4
6
5
7
8
The weight of water vapour in dry air is one of the main factors that affects the performance and
power consumption of the cabinets.
A copy of the Conformity Statement is attached to the cabinet.
Declaration of
If the original copy of the Conformity Statement provided with the cabinet
conformity
is lost, download a copy, filling out the form found at the internet address:
for Italy: https://www.arneg.it/it/dichiarazione-di-conformita-del-prodotto
for other countries:
https://www.arneg.it/en/declaration-of-product-conformity
9. Identification - Rating Plate
The serial plate containing all technical specifications (Fig.2) is affixed to the side of the cabinet:
No.
1
logo/name of the manufacturer
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
operating electrical power absorbed in the defrosting phase
6
(armoured heaters+hot wires+ fans+lighting)
7
usable display surface
8
type of refrigerant fluid used by the system to operate
9
environmental climatic class and temperature of reference
10
number of the job order based on which the cabinet has been manufactured
11
number of purchase order based on which the cabinet has been put in production
12
year of manufacture of the cabinet
13
EAC marking
14
operation class
weight of refrigerant gas loaded in every system
15
(only for cabinets with a built-in motor)
16
heating capacity
17
lighting power (where included)
18
class of protection against humidity
19
QR code
20
operating current consumption
operating electrical power absorbed in the refrigeration phase
21
(fans+hot wires+lighting)
22
Power supply frequency
i
For assistance, indicate to the manufacturer:
- the product name (2); the serial number (4); the job order number (10)
UNDER NO CIRCUMSTANCES remove the serial plate
40
Temperature
dry bulb
Humidity
°C
20
16
22
25
30
27
40
35
23.9
Relative
Dew
point
%
°C
50
9.3
80
12.6
65
15.2
60
16.7
55
20.0
70
21.1
40
23.9
75
30.0
55
14.3
Name
Weight of water
vapour in dry air
g/kg
7.3
9.1
10.8
12.0
14.8
15.8
18.8
27.3
10.2