22. 8 Inspect the parts
Once you have completed saniti zing, rinsing and drying, proceed as follows:
Step
1
check that all parts are perfectly clean and dry.
2
check that they are not damaged or too worn.
3
replace the worn parts with new parts provided solely by the manufacturer.
4
install the parts while they are perfectly dry.
5
restore electrical power supply.
Once the internal operati ng temperature has been reached, it is possible to load the products.
23. Load the refrigerant
DANGER! Coolant gas. Explosion. Asphyxia, alterati on of cardiac pace, frostbite, anaes-
theti c eff ects.
BEFORE ANY OPERATION EMPTY THE ENTIRE SYSTEM!
WARNING! FIRE. Burns. Asphyxia
NEVER use naked fl ames and electrical tools next to gas
Only specialist technicians may recharge the refrigerant or work on the gas circuit according
to the European Regulati on 842/2006
Check that refrigerant circuit is perfectly sealed
Only use original approved spare parts
i
To fi ll with refrigerant, refer to system user's manual.
24. Dismantle the cabinet
i
This product is made up for 75% of recyclable materials
• recover the coolant
Preparati on
• remove the lubricati ng oil
• dismantle the cabinet in accordance with the local laws on waste disposal and
Obligati ons
• according to the legislati on in force, the cabinet is considered as dangerous
• take the intact parts of the refrigerati on circuit to specialised refrigerant recy-
The user must deliver the cabinet to be dismantled at the collecti on centre
Liability
specifi ed by local authoriti es or indicated by the manufacturer for the recovery
and recycling of materials.
50
in respect of the environment in which we live
waste and falls under the category of separate collecti on and cannot be treat-
ed as domesti c waste or be sent to landfi ll
cling centres
i
all these operati ons such as transportati on and waste treatment must
only be performed by specialist and authorised technicians.
Acti on