Emergency And Test Operation - Haier HSM09RU03/R2 Manual De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation

Emergency and Test Operation

Emergency operation:
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which means
the start of this operation.
In this operation, the system automatically selects
the operation modes, cooling or heating, according
to the room temperature.
Temperature Operation
mode
ABOVE 21
O
C
COOLING
BELOW 21
O
C
HEATING
It is not possible to operate in dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch: the cooling operation
starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the
remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the
normal operation mode.
Timer
Designated
mode
temperature
NO
24
O
C
NO
24
O
C
O
C, do not use it in the normal
Air flow
AUTOMATIC
AUTOMATIC
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hsm09ru03/r2db hsm09ru03/r2Hsm09ru03/r2db2hum18r03/r22hum18r03/r2dbHsm12ru03/r2Hsm12ru03/r2db

Tabla de contenido