Descargar Imprimir esta página

On/Off Button; General Operation; Optional Operation - mundoclima MUP-HN Instrucciones De Instalación

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
OPERATION OF WIRELESS REMOTE CONTROL
Names and functions of wireless remote control
Note: Be sure that there are no obstructions between receiver and remote controller; Don't drop or throw the remote control; Don't let any liquid in the
remote control and put the remote control directly under the sunlight or any place where is very hot.
Notice: This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model dosen't
have, if press the corresponding button on the remote controller that the unit will keep the original running status.
+ button
For presetting temperature increasing. Press this button,can set up the temperature,
when unit is on . Continuously press and hold this button for more than 2 seconds, the
corresponding contents will be changed rapidly, until unpress the button then send the
information, °C (°F) is displaying all along. In Auto mode, the temperature can not be set
up, but operate this button can send the signal. Centigrade setting range :16-30;
Fahrenheit scale setting range 61-86.
- button
Presetting temperature can be decreased. Press this button, the temperature can be set
up, continuously press this button and hold for two seconds, the relative contents can
quickly change, until unhold this button and send the order that the °C (°F) signal will be
displayed all the time.The temperature adjustment is unavailable under the Auto mode,
but the order
can be sent by if pressing this button.
TIMER button:
By pressing this key under switch-off state, you may set the time for auto switch-on. The
range of setting is 0.5 ~ 24 hours. The
characters "T-ON" and "H" will flash for 5 seconds. Within 5 seconds,you may make one

General operation

About AUTO RUN:
When AUTO RUN mode is selected, the setting temperature will not be displayed on
the LCD, the unit will be in accordance with the room temp. automatically to select
the suitable running method and to make ambient comfortable.
About LOCK:
Under switch-on or switch-off state, you may hold "+" and "-" key simultaneously to
lock and unlock the keypad. When locked, the display will show the LOCK icon, in
which case the lock icon will flash three times upon operation of any key. After the
keypad is unlocked, the lock icon on the display will be hidden. After being energized,
the default is unlock..
About switch between º F a ºC:
Under switch-off state, you may hold "-" and "MODE" keys simultaneously to switch
15

ON/OFF button

Press this button, the unit will be turned on,
press it once more, the unit will be turned off.
When turning on or turning off the unit, the
Timer, Sleep function will be canceled, but the
presetting time is still remained.
MODE button
Press this button, Auto, Cool,Dry, Fan, Heat
mode can be selected circularly.Auto mode is
default while power on. Under Auto mode,the
temperature will not be displayed; Under Heat
mode, the initial value is 28°C (82°F); Under
other modes, the initial value is 25°C (77°F)
AUTO
COOL
HEAT
FAN
AUTO
COOL
DRY
FAN
(Only for cooling and heating unit)
HEAT
1-After powered on, press ON/OFF button,
the unit will start to run.(Note: When it is
powered off, the guide louver of main unit
will close automatically.)
2. Press MODE button, select desired
running mode, or press COOL or HEAT
mode to enter into the corresponding
operation directly.
3. Pressing + or - button, to set the desired
temperature. (It is unnecessary to set the
temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can
select AUTO, FAN 1, FAN 2, FAN 3 or FAN 4.
5. Pressing SWING button, to select the
swing.
MUP-HK
SLEEP button
Press this button, Sleep On and Sleep Off can be selected. After
powered on,Sleep Off is defaulted. After the unit is turned off, the
Sleep function is canceled. After Sleep function set up, the signal
of Sleep will display. In this mode, the time of timer can be
adjusted. Under Fan and Auto modes, this function is not
available.
FAN button
By pressing this key, you may select AUTO, FAN 1, FAN 2, FAN 3
or FAN 4, and may also cycle between them. FAN 4 only in cool
or heat mode. After being energized, AUTO is defaulted. Only
LOW fan can be set under DRY mode, pressing this key can not
adjust the fan speed, but can send message.
DRY
SWING button
Press this key to activate or deactivate the swing.
press of this key to complete the setting and send the message.If the
setting is valid, the set time will be displayed for 2 seconds before
display of the temperature message. During flash, you may press "+"
key to increase the value and press "-" key to decrease the value. The
time will increase or decrease by 0.5 hours with each press of this key.
If pressing "+" or "-" key continuously, the time value will change rapidly.
The remote controller can increase the set time by 0.5 hours every 0.25
seconds. After being energized, the fault is no timer setting, and there is
no display of "T-ON" or "H". Press ON/OFF key to switch on the unit and
cancel the auto switch-on.When the temperature display becomes
constant, you may press
this key again to display the remaining set time. The time value, "T-On"
and "H" will display constantly for 2 seconds. After 2 seconds,the preset
temperature will be displayed. Within these 2 seconds, you may press
this key again to cancel the auto switch-on and send the message.
By pressing this key under switch-on state, you may set the time for auto
switch-off.
The method of setting as the same as forauto switch-on.

Optional operation

1. Press SLEEP button, to set sleep.
2. Press TIMER button, can set the scheduled timer on or timer off.
between °C and °F
About Lamp
Under switch-on or switch-off state, you may hold "+" and "FAN" key
simultaneously for 3 seconds to set the lamp on or off and send the
code. After being energized, the lamp is defaulted on.
About BLOW over heat:
When the unit is running in Heat mode or Auto Heat mode,
compressor and indoor fan is running, to turn the unit off, the
compressor, outdoor fan will stop running. The upper and lower
guide board rotate to horizontal position, then the indoor fan will run
at low fan speed, 10s later, the unit will turn off.
GB

Publicidad

loading

Este manual también es adecuado para:

Mupr-hgMup-hk