LAMP SOCKET
BRACKET
LIGHT
PANEL
To change the depth of bulb sockets:
- Remove bottom pan (See Step 10).
- Remove 2 Light Panel Screws and Light Panel. Set
screws aside.
- Loosen 2 Screws holding Lamp Socket Bracket to
Light Panel.
- Adjust socket/bracket to desired depth.
- Re-tighten screws securely.
- Re-attach light panel and bottom pan.
INSTALL THE DUCTWORK
(Ducted Hoods Only)
ROOF CAP
SOFFIT
CABINET
HOOD
HOOD
24" - 30" ABOVE
COOKING SURFACE
1
Determine whether hood will discharge vertically (3¼" x
10" or 7" Round), or horizontally (3¼" x 10" only).
2
Decide where the ductwork will run between the hood
and the outside.
3
Choose a straight, short duct run to allow the hood to
perform most efficiently. Long duct runs, elbows and
transitions will reduce the performance of the hood. Use
as few of them as possible. Larger ductwork may be
required for best performance with longer duct runs.
4
Install wall cap or roof cap. Connect metal ductwork to
cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
SCREWS
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
PREPARE HOOD LOCATION
5
Use the proper diagram below, for placement of ductwork
and electrical cutout in cabinet or wall. For a non-ducted
installation, DO NOT cut a duct access hole.
HOOD MOUNTING SCREWS (5)
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
CABINET FRONT
CABINET
BOTTOM
4½"
¾"
WOOD SHIMS
(recessed-bottom
cabinets only)
WOOD SHIMS
(recessed-bottom
cabinets only)
4"
CABINET
BOTTOM
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
HOOD
MOUNTING
SCREWS (5)
HOOD MOUNTING SCREWS (5)
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
4
*
Note the extra wood shim and mounting screw near the
cabinet front, on the cabinet center line.
QP3 SERIES
3¼" X 10"
VERTICAL DUCTING
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
*
7 /
6
"
8
5¼"
5¼"
11"
1 /
2
"
VERTICAL DUCT
8
ACCESS HOLE
ELECTRICAL
ACCESS HOLE
CENTER
(in cabinet bottom)
LINE
3¼" X 10"
HORIZONTAL DUCTING
3
1
/
"
3
CABINET FRONT
8
/
"
3
8
*
HORIZONTAL DUCT
ACCESS HOLE
5¼"
5¼"
6
/
"
7
8
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
MAKE-UP AIR
DAMPER ELECTRICAL
CENTER
CONNECTION HOLE
LINE
5 /
11
" (30" hood)
8
5 /
14
" (36" hood)
8
5 /
17
" (42" hood)
8
8" DIA.
*
HOLE
6
7
/
"
8
7-IN. ROUND
7-IN. ROUND
DUCT
DUCT
11"
2
/
"
1
ACCESS
ACCESS
8
/
"
5
HOLE
HOLE
8
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
Page 5
7 /
10
"
8
5 /
2
"
8
/
"
5
8
ELECTRICAL
ACCESS
HOLE
(in wall)
(in wall)
7-IN. ROUND
DUCTING
10
/
"
7
8
2
/
"
5
8

Publicidad