Installation
Installation must be executed by qualified personnel in compliance with local regulations.
EQUIPMENT HOOK-UP
The oven is not provided with power supply cable. When connecting the appliance electrically, an automatic
RCD must be interposed with an opening distance between contacts of at least 3 mm. To connect the
appliance electrically it is essential to proceed in the following way:
•
Raise the cover of the terminal block.
•
Connect to the terminal block the power cable.
The power supply cable must be of H07-RNF type, with approved minimum cross section as prescribed by the
specific directive.
The electrical outlet must be easy to access, no moving should be necessary.
It is mandatory that the electrical system is equipped with a ground connection.
The appliance must be part of an equipotential system. The connection is done on terminal
marked with symbol which you will find near the cable clamp. The section of the equipotential
wire must be at least 10 mm2.
The equipotential symbol is showed in the following figure.