Recipes
BlueRhino.com/recipes
Installing LP Gas Tank
To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
grill.
Inserting LP Gas Tank
Place precision-filled LP gas tank upright into the notches in the right cart frame so the tank
valve is facing the gas line connection.
Securing LP Gas Tank
Secure tank by sliding the tank retainer wire over shoulder of LP gas tank.
Lighting
Rod
Connecting LP Gas Tank
1.
Before connecting, be sure there is no debris caught
in the head of the LP gas tank, head of the regulator
valve or in the head of the burner or burner ports.
2.
Connect regulator/hose assembly to tank by turning
knob clockwise until it stops.
Disconnecting LP Gas Tank
1.
Before disconnecting, make sure the LP gas tank valve
is "CLOSED."
2.
Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this grill.
3.
Place the protective cap cover on the LP tank and
store the tank outdoors in a well ventilated area out of
direct sunlight.
Need
Propane?
Available at:
Need help? 1.800.762.1142
Do not return to place of purchase.
20 lb
9 Kg
12.2 in. / 31 cm
Replacement Parts
parts.BlueRhino.com
1.800.762.1142
Installing Natural Gas Line
Installation should be done by a qualified service person.
W CAUTION: If young children are in the area, a locking valve should be
considered.
Connecting Natural Gas Line
1.
Before connecting, be sure there is no debris caught in
the head of the natural gas line, head of the grill natural
gas line or in the head of the burner or burner ports.
2.
Connect grill natural gas line to natural main gas line.
Disconnecting Natural Gas Line
1.
Before disconnecting, make sure the natural gas main
line valve is "OFF."
2.
Disconnect grill natural gas line from natural gas main line.
Operating Instructions
Checking for Leaks
Burner Connections
1.
Make sure the regulator valve and hose
connections are securely fastened to the burner
and the tank.
2.
Visually check the connection between the
burner/venturi tube and orifice.
3.
Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect this
connection or follow these instructions
could cause a fire or an explosion
which can cause death, serious bodily
injury or damage to property.
4.
Please refer to diagram for proper installation
(Figures 1).
5.
If the burner/venturi tube does not rest flush to the
orifice, as shown, please contact 1.800.762.1142
for assistance.
Tank/Gas Line Connection
1.
Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2.
Make sure control knobs are in the " OFF"
position (Figure 3).
3.
LP: Connect LP gas tank per "Installing LP Gas
Tank" section.
NG: Connect NG main line per "Installing Natural
Gas Line" section.
4.
LP: Turn LP gas tank valve to "OPEN."
NG: Turn "ON" natural gas main valve.
5.
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 3).
a. LP: If any bubbles appear, turn LP gas tank
valve to "CLOSED," reconnect and re-test.
NG: If any bubbles appear, turn natural gas
main valve "OFF," reconnect and re-test.
b. LP: If you continue to see bubbles after
several attempts, turn LP gas tank valve to "CLOSED" and disconnect LP gas tank, per
"Disconnect LP Gas Tank" section. Contact 1.800.762.1142 for assistance.
NG: If you continue to see bubbles after several attempts, turn natural gas main valve to
"OFF." Disconnect natural gas line and contact 1.800.762.1142 for assistance.
c. LP: If no bubbles appear after one minute, turn LP gas tank valve to "CLOSED," wipe
away solution and proceed.
NG: If no bubbles appear after one minute, turn natural gas main valve to "OFF," wipe
away solution and proceed.
9
X
X
Figure 1
LP Gas Valve
with Orifice
Burner/
Venturi
Valve
Tube
Soft Pipe
Connection
Figure 2
OFF
APAGADO
Figure 3
X
X
X
X
X