Electrical Connection - Foster 7330245 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 87

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Monophase 230V~1P+N:
Use the green/yellow cable as heart cable, the blue and the brown cable as neutral N and the
black and the grey cable as phase L.
Biphase
400V~2P+N:
Use the green/yellow cable as heart cable, the blue and the brown cable as neutral N, the grey
cable as phase L1 and the black cable as phase L2.
Before making the connection, we strongly advise you to locate the phase(s), neutral and earth
on the mains. If you have any doubts, call your electrician.
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
33
Protection calibre
25 A *
16 A *

Publicidad

Tabla de contenido
loading

Tabla de contenido