D.2 - Using Venetian mode – for a shutter with tilting slats which open one after the other
Note: • The following commands can be sent using a radio transmitter or the wall-mounted controller connected to the motor's bus line. • To identify the cited posi-
tions, refer to the figure in par. D.1.
• Enabling Venetian mode
Hold down key t (or s) for 3 seconds: the motor will move the shutter's hook to the partly open position (= position "B", as set in procedure D.1).
• Setting the number of open slats (Venetian mode)
Press key s (or t) briefly to adjust the number of open slats as desired. The motor will only operate in hold-to-run mode, and the settings must be within the limits set
in procedure D.1 (between positions "1" and "A").
• Disabling Venetian mode
Hold down key s (or t) for more than 6 seconds: the motor will completely close the shutter's slats, moving in the corresponding direction.
E - Total or partial deletion of memory
This procedure allows you to choose under point 05 the data that you want to delete.
E.1 - Procedure performed with a transmitter memorized
Before starting the procedure, bring the rolling shutter to the midpoint of its stroke.
01. Keep the n key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
02. Keep the s key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
03. Keep the n key and wait for the motor to perform 3 movements. Upon completion, release the key.
04. Keep the t key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
05. • To cancel the entire memory: keep the s and t keys pressed and wait for the motor to perform five movements. Upon completion, release the keys.
• To delete only the memorized transmitters: do not press any key and wait until the motor performs five movements.
• To delete only the limit switch heights and intermediate heights: keep the n key pressed and wait for the motor to perform 5 movements. Upon comple-
tion, release the key.
01
5
sec.
04
3
5
sec.
Note – During the procedure, you can abort the program at any time, by allowing 30 seconds to elapse between key presses.
02
2
3
5
sec.
05
all
data
5
sec.
05
only
5
5
sec.
05
"0"
"1"
5
"..."
sec.
03
3
5
sec.
5
5
English – 9