ENGLISH
to the wall. See fi g. 11 B+C.
12. Fit the ornamental stones (part 12) against the back of the
side frames using the relevant screws, see Fig. 4. These
are adjusted after being mounted on the surround.
4.2 Chimney and fl ue pipe
•
The product can be connected to a chimney and fl ue pipe
approved for solid fuel products with fl ue gas temperatures
as specifi ed in "2.0 Technical data" in the "Jøtul F 370
sAdvance" manual.
•
The cross section of the chimney must be at least that of
the fl ue pipe. See "2.0 Technical data" in the "Jøtul F 370
Advance" manual when calculating the correct chimney
cross section.
•
Several solid fuel products can be connected to the same
chimney system if the chimney cross section is adequate.
•
Connection to the chimney must be performed in accordance
with the installation instructions of the chimney supplier.
•
Make sure that the fl ue pipe rises all the way between the
product and the chimney at the rear outlet.
•
Please note that it is extremely important for connections
to have a degree of fl exibility.
For recommended chimney draught, see "2.0 Technical data"
in the "Jøtul F 370-Advance" manual.
Flue pipe at top outlet - fi g. 5
The product is supplied from the factory with smoke outlet fi tted
for the top outlet. A 60 mm offset pipe (optional extra) must be
used when top-mounting a fl ue pipe or steel chimney.
1. Place the gasket on the edge of the offset pipe (Fig. 5A).
2. Fit the end of the offset pipe with the gasket into the smoke
outlet (Fig. 5B).
3. Check that the whole of the gasket is correctly positioned.
4. Remove the knockout in the valve plate 1 and 2 (part 19+20)
on the top of the product.
4.3 Installation
Necessary tools: Spirit level, measuring tape and rubber mallet.
NB: The base must be level. Max. 1 mm/m tolerance. This is
extremely important to ensure that the rest of the installation is
correct.
All stones must be level. This has to be checked for each new
layer of stones.
Important!
Bear in mind that the soap stones may be damaged if they
are handled roughly. Do not knock the mounting brackets
too hard. Installation should be carried out by a qualifi ed
person.
The soap stones are heavy and should be handled with care
during unpacking. Place unpacked stones on a soft base.
22
The surround consists of the following
parts – see fi g. 6:
Part Designation
1
Bottom stone
2
Bottom stone w/ knockout
3
Soap stone, bottom layer
4
Side stone w/ convection hole, right
5
Side stone w/ convection hole, left
6
Cover for convection hole
7
Load-bearing plate
8
Locking bracket
9
Cover plate, lower
10
Side cartridge, left
11
Side cartridge, right
12
Ornamental stone
13
Cover plate, upper
14
Wedges
15
Side stone (2 extra)
16
Side stone for smoke outlet, left
17
Side stone for smoke outlet, right
18
Top stone
19
Valve plate 1
20
Valve plate 2
21
Flex hose (optional extra, art. no. 51012164)
22
Hose clamp (optional extra, art. no. 51012164) 1
23
Nut
24
Spacer sleeve
25
Threaded bolt
26
Screw, for ornamental stone
27
Mounting bracket, single w/ angle
28
Mounting bracket, 3/2 - left
29
Mounting bracket, double w/ angle
30
Mounting bracket, single
31
Mounting bracket, 3/2 - right
32
Screw, M8 x 16
33
Floor plate (optional extra)
35
Valve plate
36
Valve handle, surround
37
Middle piece, valve handle
38
Door handle, surround
39
Door handle dummy, surround
40
Locking nut M8
41
Washer Ø8
42
Locking bracket, top
1. The two bottom stones (parts 1 and 2) are put in place. See
fi g. 7. Check using a spirit level, then adjust as necessary. It
is extremely important that the bottom plate be steady and
level.
2. Fit the bottom layer using soap stone (part 3). Start with the two
rear stones with convection holes (parts 4 and 5). See fi g. 8.
Adjust the stones so that the joints are fl ush with the joints
in the bottom plate, fi g. 8A. Also make sure that the edges
of the bottom stones are at the same distance all the way
around, fi g. 9B.
3. Insert the two covers for convection holes (part 6) on the
back, fi g. 10. The covers are attached onto the surround
by folding the two tabs to the side on the inside of the hole.
Make sure that they fi t snugly.
4. Put the load-bearing plate (part 7) in position. See fi g. 9C.
NB! It is extremely important that the plate is the right way
round. The slot must be on the right-hand side. See fi g. 9 D.
5. When using an external air connection (optional extra, cat.
no. 341296), this has to be fi tted now. Position the burn
chamber in the four holes in the load-bearing plate, fi g.
Quantity
1
1
6
1
1
2
1
1
1
1
1
4
1
2
16
1
1
2
1
1
1
4
4
4
8
22
2
8
2
2
5
1
1
1
1
1
1
2
5
2