ND 3401-1 61-085/086 Vol-Con In
• Testing for
"Grounded" Side of
Motor or Appliance
With power to motor or
appliance "Off," touch
one test prod to the
frame and the other
prod to each of the terminal connec-
tions. The terminal which turns the
continuity LED "On" is the grounded
side. With power to motor or appliance
"On," place tester across the frame and
to each of the terminal connections.
The terminal which does not give a volt-
age indication, but does give a continu-
ity indication, is the grounded side.
• Testing for 25 to 60 Cycle
Frequency
Place tester between each side of AC
line. A low frequency hum and slow
vibrations indicate 25 cycle current. 60
cycle current is indicated by a higher
frequency hum and more rapid vibra-
tions.
• Checking Continuity of Cords,
Motors, Appliances, etc. (61-086
only)
Remove power source and place tester
across circuit to be tested. Continuity
LED turns "On" and an audible beep is
heard if resistance is less than 500K
ohms.
• Locating Excessive Leakage to
Ground
Place tester across the neutral terminal
1/9/07
4:29 PM
Page 7