p p p
TERMINAL DESCRIPTION
1
- Auxiliary power supply providing 12-24 volts dc only in ac voltage
version to actuate pulse generators up to 50 mA.
Note: For the dc power supply, this terminal is used for the direct current
positive input.
2
0 Volt or common - for use with the sensor power supply, inputs A, B and
C, and solid-state outputs 1 and 2
3
Input A (see the Role of counting and control inputs parameter)
4
Input B (see the Role of counting and control inputs parameter)
5
Input C - Programmable for use as a 0 reset input or gate (see Role of
counting and control inputs parameter)
6
Solid-state output provides a PNP output signal
7
Changeover output 1: NC
8
Changeover output 1: NO
9
Changeover output 1: Common
10
Alternating current input - neutral (not wired for dc power supply
products)
11
Alternating current input - line (not wired for dc power supply products)
12
Do not connect
13
Solid-state output provides a PNP output signal
14
Do not connect
15
Changeover output 2: NC
16
Changeover output 2: NO
17
Changeover output 2: Common