6 - Timer mode

6.1 - Description of the timer mode

" . . 
Inputs A, B and C:
- Input A : Measurement of duration of maintenance of input A or time
elapsed between two rising edges on A.
- Input B : manual, electrical or automatic resetting when active.
- Input C: Display maintained when active.
- Activation of contact OUT2 when the value P2 is reached.
- Activation of contact OUT1 when the value P1 is reached.
where:
- P1: intermediate preset.
- P2: main preset.
Note: In the case of a counter with only one preset, P1 is the main preset.
- The output OUT2 is activated, or not, on an intermediate reset, according
to the counter user settings. For units with a single preset, the
corresponding output is OUT1.