English
Operator troubleshooting
Most minor problems can be resolved quickly and easily using the table below.
If problems persist, contact a metabo HPT authorized service center for assistance.
PROBLEM
Power switch doesn't turn on.
Turn on once, but turn off
automatically.
Stapler doesn't operate
(Power switch ON).
Stapler operates, but no staple
is driven.
Weak drive.
Slow to cycle.
Drives too deep.
Skipping staples.
Intermittent feed.
Staples jam.
Driven staple is bent.
28
CHECK METHOD
Low battery charge.
Damaged internal electronics.
Push lever and/or trigger is ON state ?
Keep no operation over 30 minutes ?
(Auto-power off function)
Stapler not enough pressed against
workpiece.
Trigger not enough pulled.
More than 2 seconds pass from push
lever ON to trigger ON (or trigger ON to
push lever ON).
(Time out function)
Lock lever (Trigger lock function) is
"ON" position.
Machine is too cold (below 23°F (-5°C))
or too hot. (LED light blinks at regular
intervals, and power switch goes off
after 10 seconds.) (Refer to page 18)
Damaged internal electronics.
Magazine is dirty.
Check for a jam.
Driver blade worn or damaged?
Ribbon spring weakened or damaged? Replace ribbon spring.
Staple feeder damaged?
Check for proper staples.
Check position of stapling depth
adjustment adjuster.
Driver blade worn?
Compressed air pressure has become
low.
Damaged internal electronics.
Check position of stapling depth
adjustment adjuster.
Check for proper staples.
Staple feeder damaged?
Ribbon spring weakened or damaged? Replace ribbon spring.
Driver blade worn or damaged?
Check for proper staples.
Driver blade worn or damaged?
CORRECTION
Charge the battery.
Contact metabo HPT for inspection.
Keep push lever and trigger in OFF
state.
Push and hold power switch more than
1 second to switch "ON"
Hold stapler fi rmly and press to the
workpiece completely.
Pull the trigger fi rmly.
Make sure that less than 2 seconds
pass between push lever ON and
trigger ON (or between trigger ON and
push lever ON).
Set Lock lever to "OFF" position. (Refer
to page 19)
Allow the stapler to cool or warm-up
throughly in adequate condition.
Contact metabo HPT for inspection.
Blow and wipe clean the magazine.
Clear a jam (refer to page 25).
Contact metabo HPT for inspection.
Replace staple feeder.
Use only recommended staples.
Readjust according to page 24.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Contact metabo HPT for inspection.
Readjust according to page 24.
Use only recommended staples.
Replace staple feeder.
Contact metabo HPT for inspection.
Use only recommended staples.
Contact metabo HPT for inspection.