HUMIDITY CONTROL
3) The hygrometer on the cord reads the current room humidity and displays the
percentage on LCD panel.
4) To set the desired humidity, press the HUMIDITY button. Each successive
push increases the humidity in 5% increments. The range is 25% to 65%.
5) At 65% the humidifier will run constantly with or without water.
NOTE: If excessive condensation occurs, reduce fan to a lower speed setting.
CHECK FILTER
The ability of any humidifier to efficiently supply humidity output relies heavily on the
condition of the filter. As the filter loads with impurities it gradually loses its wicking
capability. When this happens, moisture output is reduced and the humidifier has to work
longer to satisfy the selected setting.
1) This humidifier has a check filter reminder timed to appear after
720 hours of operation. When the Check Filter (CF) message is
displayed, disconnect the power cord and check the condition of
the filter. If a build-up of deposits or severe discoloration is
evident replace the filter to restore maximum efficiency.
2) The CF function is reset after plugging the unit back in.
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
ACTIVATION PROCEDURE
Control Lock
After the humidifier functions have been set up, hold the Speed and
Display
Humidity buttons down for 5 seconds. The display will show "CL"
for 2 seconds;
Release the buttons and the control will resume the display of the room humidity.
The humidifier will continue to function with the locked in settings. If buttons are
operated while "CL" is active, the "CL" is displayed and settings are unaffected.
DEACTIVATION PROCEDURE
To deactivate the "CL" function simply press and hold both buttons for 5
seconds. "CL" will flash at the rate of 1 second on and 1 second off for a period
of 2 seconds and then resume the display of room humidity.
REPLACEMENT OF WICK
CAUTION: Before changing wick, ensure unit is turned OFF and unplugged.
NOTE: This unit uses 2 model 1040 wicks. Replace the wick at the beginning of
each season, and more often in areas with hard water.
Remove water bottles from the humidifier and place them in a secure place. Locate
the two internal spring latches on the front and rear of the base. Releasing these
latches will allow removal of the top housing.
1) Flex the rear latch and lift the back of the top housing off the base far enough to
clear the latch. Flex the front latch and lift the complete top housing away from the
base. Place the top housing on a flat surface.
6
Check Filter
Function Display