DUO-FAST 903000 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Fuel Cell and Metering Valve
Inserting Fuel Cell
Inserting the metering valve/fuel cell assembly into the
Cordless Framing Nailer is very simple. To begin, press up
at the bottom of the actuator cover and pivot outward to
open. The cover will swing out of the way.
1. Press Up
2. Pull Out
Next, with the metering valve stem pointed toward the front
of the tool, insert the metering valve/fuel cell assembly.
Metering Valve.
Stem Pointed
Forward.
12
As you slide the metering valve/fuel cell assembly into the
Cordless Framing Nailer, you will notice a red adapter at the
top of the cylinder pocket. As shown in the illustration, this
adapter is designed to ensure that the metering valve stem
is properly aligned with the small hole, or orifice, that leads
to the combustion chamber. Insert the metering valve stem
into the orifice of the red-colored adapter.
Metering
Valve Stem
Red Metering
Valve
Close the actuator cover to complete the loading of fuel in
the Cordless Framing Nailer. Do this by swinging it up and
over the fuel valve/cylinder assembly, and pushing down
until the actuator cover snaps into position.
1. Swing Up
2. Push Down
Red Adapter
Fuel Cell