GB
The 4-wire video-intercom kit can easily be installed by non-spe-
cialized technicians or do-it-yourself enthusiasts. It consists of one
monitor with 4" flat screen powered by a transformer connected to
the A.C. network, one entrance panel serie "PATAVIUM" complete
with CCD camera and outdoor unit, one transformer.
This installation may be expanded by adding extra monitors
and/or interphones, a call repeater relay and other useful
accessories may be supplied on request.
OPERATING PRINCIPLE
Carry out connections as described in this leaflet. When entrance
panel push-button is pressed, a call signal is heard and the monitor
comes on immediately,showing a clear image of the caller.
Lift handset to communicate with caller and if required operate the
electric lock by pressing the push-button with the key symbol.
The monitor turns off automatically after about 30".
The installation can be switched on from the inside by pressing the
push-button with the
when required.
TECHNICAL CHARACTERISTICS OF MONITOR (ART. 63M7).
-
Surface wall-mounting housing in ABS plastic, available in white,
white/black or black.
-
Back plate and fixing screws for wall mounting (supplied in pack-
ing).
-
CRT with 4" flat screen.
-
Electronic circuit on interchangeable card.
-
Standard CCIR, 625 lines, 50 images (Standard EIA on request).
-
4MHz pass band.
-
Input signal 1-2Vpp on 75 Ohms.
-
Operating temperature: 0° C + 40° C.
-
Built-in adjustable electronic chime.
-
3-position variable chime volume adjustment.
-
Brightness control
-
Contrast control
-
Push button
for electric lock release .
-
Auto-switching push-button
-
Push button
for auxiliary functions (stair-light, etc.).
-
15V A.C. supply voltage
-
Camera supply output
-
Dimensions: 204x220x71
-
Weight: Kgs. 1.5 without packing.
TECHNICAL CHARACTERISTICS OF CAMERA (ART. 63U7/V)
-
CCD 1/4" sensor
-
3,7 mm F4.5 lens with fixed focus
-
Brightness automatic control
-
Video signal standard CCIR, 625 lines, 50 images (standard EIA
on request)
-
Video output voltage 1Vpp on 75 Ohms
-
Operating temperature -5° +50° C.
-
Infrared subjet lighting.
-
Name-tag lighting by means of LED diodes.
-
Built-in speech unit
-
Removable terminal block for connection (point "F").
-
12V D.C. 150mA supply provided by monitor.
-
Dimensions: 120x80x25 mm
-
Weight: Kgs. 0.6 without packing.
TECHNICAL CHARACTERISTICS OF TRANSFORMER
(Art. 832/030)
-
4 -Module DIN housing in ABS plastic
-
230V 50Hz supply voltage (other voltages on request)
-
15V A.C. 30VA output voltage
-
Internal protectedion against short-circuits with PTC
-
Dimensions: 75x90x65
-
Weight: Kg. 0.76 without packing.
MONITOR INSTALLATION
Install monitor far from sources of heat and light.
Fig. 1 - Fix the monitor hooking plate to the wall (its base mounted
at 1.40 m. from floor level).
Carry out connections on monitor terminal block by following
drawing on page 9 or version of basic diagram on pages 10-
14.
symbol, thus allowing an external view
Fig. 2 - After connecting cables to terminal block, insert monitor fol-
lowing arrows 1 and 2.
Fig. 3 - Slide "A" adjusts the call volume; knob B adjusts brightness.
Knob C is to adjust the contrast;
push-button "D"
operates electric lock;
push-button "E"
is used for auxiliary functions (stair-light, etc.).
push-button "F"
is used to switch on installation from the monitor;
Fig. 4 -
It is possible to change this monitor into a desk version by
using proper transformation desk kit Art. 6610.
NOTES:
The installation ensures a good operation if connected with 30 m.
cable type 63CV (supplied separately) and also if a 12V A.C. 10VA
electrical door lock is connected
If longer distances up to max 100m are required, increase cable sec-
tion. Use coaxial cable type RG59.
ENTRANCE PANEL FOR VIDEO DOOR ENTRY SYSTEMS
INSTALLATION
Before installing equipment, choose location for camera entrance
panel: the camera shouid be protected from direct light (sun, car
headlights, etc.) as this may affect the quality of the picture, and may
damage the camera. This camera is equipped with infrared Leds
allowing perfect picture at one metre distance.
It is advisable to protect panel with some form of weatherproof shel-
ter.
Fig. 5 - These drawings show the components of the panel:
A - Front plate
B - Camera
C - Back-box
D - Security clamp
E - Removable terminal block for connecting the camera
Fig. 6 - Split the flush-mounted back box from the panel, flush-mount
back box with top at 1,65 m. from ground level.
Fig. 7 - To gain access to the name-tags, take out the name-tag hold-
er from the rear, as shown in the drawing.
INSTALLATION OF SUPPLY TRANSFORMER
4-DIN module supply transformer Art. 832/030 may be wall mounted
with long fixing screws (supplied) or on a box equipped with DIN sup-
port. It is advisable to connect supply network with a double pole
fused isolator.
This transformer is equipped with thermic protectedion (PTC) so that,
in the event of a short-circuit to the secondary supply, the protecte-
dion circuit removes the 15V secondary voltage until the fault is rec-
tified.
After cutting off power supply to the primary and after eliminat-
ing the short-circuit, it is necessary to wait for a few minutes to
allow cooling of the protectedive device, so that the transformer
may start normal operation again.
FAULT-FINDING (can be solved by users):
MONITOR OFF
Check that transformer has been conneoted correctly to mains sup-
ply.
Voltage on terminals 11 and 12 of monitor shouid be of 15V.
MONITOR ON WITHOUT PICTURE:
Check that cables between monitor and camera are wired properly
and that there are not interruptions and/or short circuits.
SCREEN.WITH ONE OR TWO HORIZONTAL BARS AND/OR DIS-
TORTED PICTURES.
Check that supply voltage to terminals M and 1 of camera is not less
than 13V. If installation still does not work, contact our maintenance
department or specialized technicians.
3