Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DT1260-TUN
OWNER'S MANUAL
Thank you for purchasing
the DynaTrap
insect trap!
®
This product may be covered by one or more U.S. patents
or pending patent applications. See wwwDynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions should
always be followed, including the following:
1. Please read all instructions before using the DynaTrap
Insect Trap and keep for future reference.
®
2. To disconnect, twist housing to the 'OFF' position, then remove plug from outlet.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when
not in use and before servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. Place out of reach from children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or if it has been dropped into water or other liquid.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
18. This appliance is provided with double insulation. Use only identical replacement parts.
See instructions or Servicing of Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. Assemble Stand: Pull the cord tight through the pole stand. Turn
base on its side and insert bottom threaded plastic piece into
base, connecting to the threaded plastic cap. Twist threaded
plastic cap clockwise to tighten. Complete installation by aligning
upper and lower support tube and inserting the bar sections.
For more detailed instructions, please refer to assembly guide.
3. Hold the power switch on the side of the revolving rotation door.
Twist the unit to the "POWER ON" position. When you hear a
"click," the machine is turned on.
4. For best catch results leave unit on at all times, except when
cleaning or servicing.
5. Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from
competing light sources.
6. It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
7. This unit is all-weather resistant - designed for outdoor use including rainy conditions.
Intended for household and commercial, indoor and outdoor use.
8. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other).
This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
9. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a
means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care
and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a
double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those
parts in the appliance. A double-insulated appliance is marked with the words "DOUBLE INSULATION",
"DOUBLE-INSULATED" or the symbol:
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire
prevention and provide for more efficient operation.
1. Be sure to clean the unit once per week.
2. To clean, hold the switch on the revolving rotation door and
twist housing to the "OFF" position. After hearing the "click,"
the machine is turned off. Unplug the unit.
3. For weekly cleaning, twist the cage clockwise and remove any
buildup from the inside of the retaining cage and fan with the
included cleaning brush.
4. For major cleaning, remove the screw securing the fan housing
to the light housing
(A),
and gently twist to separate. Do not
disconnect wires. Using the cleaning brush, remove dirt and
debris from the fan housing. Once the cleaning process has
been completed, tuck the wires into the channel of the fan
housing (D). Align the screw holes and place the light housing
model 41050.
®
on top of fan housing. Secure with a click and tighten the screw
to the base of the light housing.
IMPORTANT: When replacing the retaining cage –
DO NOT press/push against the screen windows.
5. Clean prior to off-season storage.
REPLACING BULB Replace with DynaTrap
bulb #41050
®
(or equivalent G24 Type - 56V/7W bulb)
The lightbulb life expectancy is approximately 3,000 hours (or about
4 months), and should be replaced regularly to ensure optimal UV
effectiveness. Even though the bulb's light may be visible to you, its
ability to attract mosquitoes diminishes over time.
1. Hold the switch on the revolving rotation door and turn it to the
"POWER OFF" position. UNPLUG UNIT, and allow bulb to cool
before replacing.
2. Remove the screw securing the fan housing to the light housing
(A), and gently twist to separate carefully, do not disconnect
wires. Loosen the screw securing the metal bracket
securing the light bulb
(B)
and remove the metal bracket.
Cover the bulb with a cloth to protect your fingers and hand.
Grasp the bulb (with your hand and fingers protected by the
cloth) and gently pull the bulb from the socket (C).
3. Remove any debris from the lamp socket with cleaning brush.
Insert new bulb. Reposition the metal bracket over the base of
the bulb and tighten the screw. Make sure to tuck the wires into
the channel of the light housing so the wires do not get pinched
or cut by the fan (D). Align the screw holes and place the light
housing on top of fan housing. Secure with a "click" and tighten
the screw to the base of the light housing.
HOW THE DYNATRAP
INSECT TRAP WORKS
®
Flying insects are attracted to the unit by the UV light
and CO2 that is generated by the photo-catalysis
between the UV lamps and the special TiO2 coating.
The fan then pulls the insects into the screened base,
trapping them until they dehydrate and die. The base
can be removed, allowing the contents to be periodically
emptied into the trash. Monitor the insects trapped in
the retaining cage through the see-through screen, and
empty when compartment becomes full.
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulb does not il-
1. No electrical power.
1. Check plug, receptacle and fuse or circuit breaker.
luminate and fan does
2. Check to make sure power is switched to the "ON" position.
not spin.
Bulb illuminates, but
1. Shorted fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
fan does not spin.
foreign material, dirt or buildup of dead insects.
Clean unit as in "CLEANING" section.
Fan spins, but bulb
1. Bulb not seated properly.
1. Check sockets for proper bulb seating and alignment.
does not illuminate.
2. Burnt out bulb.
2. Replace bulb if needed, following instructions under
"Replacing Bulb".
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship.
This warranty is limited to remedy any defective part for a period of one year from date of original date of
purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to,
in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not
apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC
be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any
other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied
warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights that vary from state to state.
REPLACEMENT PARTS
41050
7-Watt Replacement UV Fluorescent Bulb (1 piece)
41053
Retaining Cage
To see all replacement and accessory parts visit wwwDynaTrap.com.
FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE
Dynamic Solutions Worldwide, LLC
U.S.A. & Canada
12247 W. Fairview Ave. Milwaukee, WI 53226
1-877-403-TRAP (8727)
customercare@dsw-llc.com | www.DynaTrap.com
Mexico
4002907
Dynatrap Servicios de Mexico S. de R. L. de C.V.
This device complies with Performance Standards
01-800-880-8727 | servicios@dsw-llc.com
for Light-Emitting Products, 21 DFR, Part 1040,
©2019 Dynamic Solutions Worldwide, LLC
Chapter 1, Subchapter J, Radiological health.

Publicidad

loading

Resumen de contenidos para DynaTrap DT1260 -TUN

  • Página 1 (D). Align the screw holes and place the light housing 4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap model 41050. This warranty is limited to remedy any defective part for a period of one year from date of original date of ®...
  • Página 2 Reloj. Con el cepillo de limpieza que viene de “limpieza”. incluido, retire la acumulación de insectos del interior de la cámara 1. Por favor lea las instrucciones antes de usar la trampa para insectos DynaTrap ® y guárdelas para de retención y del ventilador.
  • Página 3 If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of To see all replacement and accessory parts available for your DynaTrap, The lightbulb life expectancy is approximately 3,000 hours (or about electrical shock, only plug into a properly installed outlet.
  • Página 4 DYNAMIC garantiza al comprador original que este producto está libre de defectos de materiales y mano de obra. Esta garantía está del ventilador y la carcasa del foco gire las carcasas suavemente Por favor lea las instrucciones antes de usar la trampa para insectos DynaTrap y guárdelas para futuras referencias. ®...