Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL: DT1210
OWNER'S MANUAL
Thank you for purchasing this
DYNATRAP
Insect Trap!
®
This product may be covered by one or more U.S. patents
or pending patent applications. See www.dynatrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
When using electric appliances, basic precautions should always be followed, including the following:
1. Please read all instructions before using the DynaTrap® Insect Trap and keep for future reference.
2. To disconnect, twist housing to the 'OFF' position, then remove plug from outlet.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when
not in use and before servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap® model 41050.
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. Place out of reach from children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or if it has been dropped into water or other liquid.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
18. This appliance is provided with double insulation. Use only identical replacement parts.
See instructions for Servicing of Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. Pull the cord tight through the pole stand. Turn base on its side and insert bottom threaded plastic piece
into base, connecting to the threaded plastic cap. Twist threaded plastic cap clockwise to tighten. Complete
installation by aligning upper and lower support tube and inserting the bar sections.
(For more detailed instructions, please refer to assembly guide)
3. Plug cord into an outdoor outlet or UL listed extension cord as described in "IMPORTANT SAFETY
INSTRUCTIONS". Turn power switch to "ON" position. The switch is located under the rain cover.
4. Small holes in the lid of the unit are designed to collect rain water automatically and fill the water tray.
If more water is needed, carefully fill tray ¾ full using a small container (do not use water hose as it
may splash too much water inside the trap). Check once a week or as needed.
5. For best catch results leave unit on at all times, except when cleaning or servicing.
6. Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit
away from competing light sources. Intended for household use only.
7. It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
8. This unit is all-weather resistant - designed for outdoor use including rainy conditions.
9. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other).
This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician to install the proper outlet.
Do not change the plug in any way.
10. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a
means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme
ALL-WEATHER
care and knowledge of the system and should be done only by qualified service personnel. Replacement parts
CONSTRUCTION
for a double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical
INDOOR/OUTDOOR
to those parts in the appliance. A double-insulated appliance is marked with the words "DOUBLE INSULATION",
RAIN OR SHINE
"DOUBLE-INSULATED" or the symbol:
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Be sure to clean the unit once per week
2. Switch the unit off and unplug before cleaning
3. For weekly cleaning, remove the screw securing the retaining cage and then twist the cage clockwise. Remove the damper
by grasping the crossbar near the edge of the damper. Pull up firmly. Remove any buildup from the inside of the
retaining cage and fan with a brush (included). Replace damper, snap firmly into place.
4. For major cleaning, remove the four screws securing the fan housing to the light housing. After removing the screws,
gently pull the fan housing away from the light housing. Using a soft brush, remove dirt and debris from the light housing.
Once the cleaning process has been completed, align the screw holes in the fan housing with the screw holes in the lighting
unit and tighten the screws to the base of the lighting unit.
5. When replacing the retaining cage – DO NOT press/push against the screen windows.
REPLACING BULB
The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure
optimal UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over time.
1. Turn power switch to "off" position. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove the screw securing the retaining cage and then remove the retaining cage by twisting the cage clockwise. Turn the
unit upside down.
3. Remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan housing
away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the cleaning process
has been completed, untighten the screw securing the base of the light bulb to the light housing. Slide the metal bracket to
the side. Cover the bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected
by the cloth) and gently pull the bulb from the socket.
4. Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal plate over the base
of the bulb and tighten the retaining screw.
5. Align the screw holes in the fan housing with the screw holes in the lighting unit and tighten the screws to the base of the
lighting unit.
6. Replace the retaining cage at the bottom of the unit.
Replacement fluorescent bulbs can be found at your local retailer or
can be ordered directly from DynaTrap by visiting www.dynatrap.com
HOW THE DYNATRAP
Flying insects are attracted to the unit by the UV light and CO
generated by the photo-catalysis between the UV lamps and the special
TiO
coating. The fan then pulls the insects into the screened base,
2
trapping them until they dehydrate and die. The base can be removed,
allowing the contents to be periodically emptied into the trash. The
see-through screen shows the insects trapped in the compartment,
alerting you when the cage needs to be emptied.
ON/OFF
SWITCH
TiO
COATED
2
INSECT TRAP WORKS
®
SURFACE
that is
2
FAN
RETAINING
CAGE
TROUBLESHOOTING
Problem:
Possible cause:
Bulbs do not illuminate
1. No electrical power
and fan does not spin.
Bulb illuminates, but fan
1. Shorted fan
does not spin.
Fan spins, but bulb does
1. Bulb not seated
not illuminate
properly
2. Burnt out bulb
LIMITED WARRANTY
DYNAMIC warranties to the original purchaser that this product is free from defective materials and workmanship. This warranty
is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original
receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit
has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, Canada
and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind
for breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an
implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights that vary from state to state.
PARTS & ACCESSORIES AVAILABLE
PART
DESCRIPTION
41050
7-Watt Replacement Fluorescent Bulb (1 piece)
41052
Fan Blade and DC Motor Ultra-Long Life Replacement
41053
Retaining Cage
41072
Retaining Cage including Automatic Damper Assembly
41065
Automatic Damper Assembly
UV BULB
Dynamic Solutions Worldwide, LLC
12247 W. Fairview Ave. Milwaukee, WI 53226
WATER
TRAY
1-877-403-TRAP (8727)
customercare@dsw-llc.com | www.DynaTrap.com
AUTOMATIC
© Dynamic Solutions Worldwide, LLC
DAMPER
Correction:
1. Check plug and receptacle and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON"
position.
1. UNPLUG UNIT: Examine fan to see that it is free from
foreign material, dirt or build-up of dead insects. Clean unit as
in "CLEANING" section.
1. Check all sockets for proper bulb seating and alignment.
2. Replace bulb if needed following instructions under
"Replacing Bulbs".
4002907
This device complies with Performance Standards
for Light-Emitting Products, 21 DFR, Part 1040,
Chapter 1, Subchapter J, Radiological health.

Publicidad

loading

Resumen de contenidos para DynaTrap DT1210

  • Página 1 4. For major cleaning, remove the four screws securing the fan housing to the light housing. After removing the screws, 1. Please read all instructions before using the DynaTrap® Insect Trap and keep for future reference. and you may also have other rights that vary from state to state.
  • Página 2 Una vez que el proceso de limpieza ha sido completado, aliene los un estado a otro. 1. Por favor lea las instrucciones antes de usar la trampa para insectos DynaTrap® y guárdelas para futuras referencias.