Table Of Contents Owner’s Guide Installation Instructions Arming the System ....... 3 How To Program Remote Control ..... 9 Disarming the System ....4 How To Program Features ...... 10 Emergency Override ....4 Programmable Features ....10 - 12 System Armed &...
Página 3
Emergency Override: THEN WITHIN 10 SECONDS PRESS & RELEASE VALET BUTTON Panic: Press & Hold the “Lock” Button for 3 Sec’s, with the ignition “Off” THE SIREN WILL SOUND THE PARKING LIGHTS Hold 3 seconds WILL FLASH Shock Sensor & Prewarn Bypass: 1) Arm the alarm by, Pressing &...
Arming the Alarm The system may be “Armed” by any of 3 methods: Remote Control Arming: Press & Release the “Lock” button THE SIREN WILL CHIRP ONCE THE PARKING LIGHTS WILL FLASH ONCE THE DOORS WILL LOCK (IF CONNECTED) 2) SILENT Remote Control Arming: Press &...
Disarming the Alarm The system may be “Disarmed” by any of 3 methods: Remote Control Disarming: Press & Release the “Unlock” button THE SIREN WILL THE PARKING LIGHTS CHIRP TWICE WILL FLASH TWICE THE DOORS WILL UNLOCK (IF CONNECTED) 2) SILENT Remote Control Disarming: Press &...
System Armed & Activated Regardless of method used to Arm the alarm, once Armed, the alarm will monitor all protected zones, and if an intrusion attempt is detected it will activate, or “trigger”. A trigger consists of the following: • The electronic siren, or optionally the vehicle’s horn, will start sounding. •...
The Auxiliary Channel The Auxiliary Channel may be used to operate an optional function. Pos- sibilities include remote trunk release, remote car starting, or an on-demand remote window roll-up interface. Please see your Omega dealer for details on available options. To Activate the Auxiliary Channel: Press &...
Programmable Anti-Carjacking Protection The Anti-Carjacking sequence may be activated by any of 3 methods: 1) Using the remote control, by holding down the Small “4th” Button for 3 seconds while the ignition is “On”. (programmable feature 2) When a door is Opened while the ignition is “On” (programmable feature 3) Every time the ignition is turned “On”.
Valet Mode Valet Mode can only be entered into while the alarm is Disarmed. Valet Mode turns off all of the alarm’s security features, (including Anti-Carjack). Valet Mode is designed for situations in which it is not convenient for the security portion of the alarm to be operational;...
Auxiliary Sensor & Prewarning Auxiliary Sensor: This security system is equipped with a plug-in port for an optional sensor to increase the effectiveness of the system. The comprehensive line of optional sensors offered is comprised of impact sensors, glass tampering sensors, and microwave/radar sensors which can detect motion inside and outside the vehicle.
How to Program Features To access Features Programming Mode: Step 1: Turn the vehicle’s ignition “On” then “Off”. Step 2: Within 7 seconds of turning the ignition “Off”, press the Valet Switch 5 times. The siren will wolf once confirming entry to Features Programming Mode.
Página 12
4. Double Pulse Unlock: ( 2 pulses = 1 siren chirp / • 1 pulse = 2 chirps) - Sets alarm to give 2 unlock pulses upon Disarm for cars that require it. 5. Immobilizer Mode: ( On = 1 siren chirp / •Off = 2 chirps) - If this mode is programmed “On”, the starter interrupt will remain engaged after the alarm is Disarmed, until the vehicle’s ignition is turned “On”...
Página 13
11. Dome-Light or Window Roll-Up: (•Dome-Light = 1 siren chirp / Window Roll-UP = 2 chirps) - Configures the alarm’s “Black/White” wire to operate the: a. Dome-Light: Supply a (-) output when the alarm is Disarmed to illuminate the vehicle’s Dome-Light for 30 seconds through the use of a relay, or b.
“RFID” ANTI-HIJACKING (Programmable Feature #14) This feature requires the use of the #410-01 RFID Remote. (Sold separately) 1) To turn “On” the remote control’s RFID function: Press & Hold the remote’s button for 5 seconds, the LED will flash to confirm the RFID function is “On”...
“RFID” Anti-Hijacking : (Programmable Feature #14) For the RFID remote control to operate with the alarm, it is necessary to pro- gram the remote to the alarm and turn “On” programmable feature #14. If programmable feature #14 is “On”, the Anti-Hijacking operation will commence every time: 1) The vehicle’s ignition is turned “On”...
Página 16
“RFID” Anti-Hijacking Operation : 1) The RFID Anti-Hijacking process is activated every time the vehicle’s igni- tion is turned “On”, or a vehicle door is opened while the ignition is “On”. 2) Upon activation, the alarm will begin to search for the RFID remote con- trol’s signal for 3 minutes.
Door Lock/Unlock pulse lengths: Jumper “ON” 0.80 Sec Jumper “OFF” 4.0 Sec Combined: SS-2 LED Status Indicator Valet/Override Button NOTE: requires a 5/16” (8mm) hole to be drilled Sensor • Main Wire Harness (H-AL16A) • Conector Central Battery Page 16...
Door Locking Systems / Sistemas De Cierre Negative Trigger System / Sistema Negativo: Doorlock Actuators Blue Green Unlock wire/ Cable de Apertura Lock wire / Cable de cierre Unlock Ground Lock Vehicle’s Doorlock Relay Control Unit Doorlock Switch Positive Trigger System / Sistema Positivo: Doorlock Actuators Blue...