K2 Pumps SPI03303TPK Manual Del Propietário página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Sump basin
NOTE: Do not reduce size of discharge pipe or hose below 1-1/2 in. diameter. If discharge is too small, pump will
overheat and fail prematurely. This pump is designed for use in a residential sump only. Only pump water with this pump.
INSTALLATION
1-1/2''
Dischrage Pipe
1/8"Anti-airlock
Hole
1. Install the pump in sump pit with minimum diameter of 10 in. (254 mm) for models equipped with vertical switches
and 14 in. (356 mm) for tethered float switch models. The sump depth should be 14 in. (356 mm) for vertically
switched models and 18 in. (457 mm) for tethered models. Construct the sump pit of tile, concrete, steel or plastic.
Check local codes for approved materials and for proper installation.
2. Install the pump in a pit so that the switch operating mechanism has maximum possible clearance.
3. The pump should not be installed on clay, earth or sand surfaces. Clean the sump pit of small stones and gravel
which could clog the pump. Keep the pump inlet screen clear.
NOTE: Do not use ordinary pipe joint compound on plastic pipe. Pipe joint compound can attack plastics.
4. Insert rigid plastic pipe into the quick connector. Hand tighten the knurling nut of the quick connector as tight as
possible.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used,
make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump
movement, switch interference and prevent the pump from starting or stopping.
5. To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. (47.6 mm) I.D., e.g. radiator hose) can
be connected into the discharge line near the pump using suitable clamps.
6. Install an in-line check valve or an in-pump check valve to prevent flow backwards through the pump when the pump
shuts off.
NOTE: If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a
1/8"(3.2mm) hole in discharge pipe about 1"-2"(2.5 -5.1cm) above quick connector. The hole must be in the
sump.
4
115V, 60 HZ., 15 Amp Circuit
32° F to 95° F (0° - 35° C)
1-1/2" or 1-1/4" with adaptor (purchased separately if using 1-1/4'' discharge pipe)
Min. 14 in. (356 mm) diameter, 18 in. (457 mm) depth for tethered switch
Min. 10 in. (254 mm) diameter, 14 in. (356 mm) depth for vertical switch
Check Valve
1-1/2''
Dischrage Pipe
1/8"Anti-airlock
Hole
For Professional Technical Support call 1-844-242-2475
Check Valve

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Spi03303vpkSpi05003tpkSpi05003vpk

Tabla de contenido