Descargar Imprimir esta página

LORCH Basic Plus Manual De Instrucciones página 21

Panel de mando

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
Control panel Basic Plus
A13 Service LED
Lights up should servicing be needed, e.g. calibration
required.
A14 Gas test/Save button
Pressing the button briefly starts the gas test for 30
sec.
If the menu is activated, then the set parameter value
is saved.
A15 Gas test LED
Lights up when the gas test is activated.
A16 Display units LEDs
Display whether values in the 7-segment display A12
are shown in metres per minute, percent, frequency,
voltage or seconds.
A19 Welding voltage LED
Lights up when the welding voltage/arc length in V
can be set using the rotary knob A44.
A20 Arc length LED
Lights up when the arc length in % can be set using
the rotary knob A44.
A21 Welding voltage/arc length button
Used to switch over between the main parameters
welding voltage and arc length.
Only available for the Synergy welding process or
optional extended processes.
A22 Interval LED
Lights up when Interval mode is selected.
A23 4-stroke individual LED
In 4-stroke IND mode, parameters are available for
starting and secondary energy.
A24 LED electrode
Lights up when the Electrode welding process is se-
lected. Hold the button A33 down for 2 seconds.
A26 Additional assignable welding processes LEDs (op-
tional)
See "8 Startup menu (Customizing)" on Page 25.
A27 Spots LED
Lights up when the Spots mode is selected.
A28 MIG/MAG Synergy LED
Lights up when the MIG/MAG Synergy welding pro-
cess is selected.
A29 4-stroke LED
Lights up when 4-stroke mode is selected.
A30 MIG/MAG Manual LED
Lights up when the MIG/MAG welding process is se-
lected.
A31 2-stroke LED
Lights up when 2-stroke mode is selected.
A32 Welding process button
Used to switch over between the welding processes
MIG/MAG, Synergy and the optionally extendible
welding process A26.
A33 Mode button
Used to switch over between the operating modes
2-stroke, 4-stroke, Spots, Interval, 4-stroke IND, and the
Electrode welding process.
02.20
A34 Wire feed speed/welding current/material thickness
button
Used to switch over between the main parameters
Wire feed speed, Welding current and Material thick-
ness.
Only available for the Synergy welding process or
optional extended processes.
A35 Material thickness LED
Lights up when the material thickness can be set using
the rotary knob A41.
A36 Welding current LED
Lights up when the welding current can be set using
the rotary knob A41.
A37 Wire feed speed LED
Lights up when the wire feed speed can be set using
the rotary knob A41.
A40 Display units LEDs
Display whether values in the 7-segment display A4
are shown in millimetres, metres per minute or Amps.
A41 Rotary knob A41
Used to set the main parameters Wire feed speed,
Welding current and Material thickness. If the menu is
activated, used to select the parameter (code).
A42 VRD LED (only for machines with VRD)
Lights up continuously when the VRD function is ac-
tive (reduction of idle voltage).
Flashes when the output voltage exceeds the value
approved in the standard (e.g. in welding operation).
A43 NFC read area (Near Field Communication)
Used to read out and write (optionally) NFC cards and
the connected functions.
A44 Rotary knob A44
Used to set the main parameters welding voltage and
arc length, as well as the electrode material. If the
menu is activated, used to set the parameter value.
A45 NFC active LED
Lights up when the user interface is ready to exchange
data with a mobile phone.
A46 F2 LED
Lights up when welding circuit resistance Compensa-
tion Mode is active.
909.3049.9-03
- 21 -

Publicidad

loading

Productos relacionados para LORCH Basic Plus