4. Installation & usage
How to determine the power requirements of your equipment
1. Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and
peripheral equipment does not exceed rated capacity.
2. Ensure that the equipment plugged into the battery power-supplied/surge outlets
does not exceed the UPS unit's rated capacity. If the rated unit capacities are
exceeded, an overload condition may occur and cause the UPS unit to shut down or
the circuit breaker to trip.
Hardware installation guide
1. Your new UPS may be used immediately upon receipt. However, recharging the
battery for at least 8 hours is recommended to ensure that the battery's maximum
charge capacity is achieved. Charge loss may occur during shipping and storage. To
recharge the battery, simply leave the unit plugged into an AC outlet. The unit will
charge in both the on and off position.
2. With the UPS unit off and unplugged, connect the computer, monitor, and any
externally powered data storage device (Zip drive, Jazz drive, Tape drive), etc. into the
battery power supplied outlets. DO NOT plug a laser printer, copier, space heater,
vacuum, paper shredder or other large electrical device into the battery power supplied
outlets. The power demands of these devices will overload and possibly damage the
unit.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the
wall branch outlet is protected by a fuse or circuit breaker and does not service
equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.
Avoid using extension cords.
4. Press the power switch to turn the unit on. The power on indicator light will illuminate
and the unit will "beep".
5. If an overload is detected, an audible alarm will sound and the unit will emit one long
beep. To correct this, turn the UPS off and unplug at least one piece of equipment from
the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker /
fuse is normal and then turns the UPS on.
6. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into
an AC outlet, the battery will automatically recharge.
7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all
times.