Descargar Imprimir esta página

jbc TE 5400 Manual Del Usuario página 4

Estación de aire caliente de precisión

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
Temperature increase
Temperature decrease
SETUP mode
selection
Vacuum pump
selection
Suction selector
for tripods and
extractors
OPERATION
Description of controls
- BUTTONS:
HEAT
HEAT
HEAT. Activates or deactivates the air flow. The
HEAT
HEAT
hot-air flow automatically turns off after the
selected time.
SUCTION. On/off switch for the self-contained
SUCTION
SUCTION
SUCTION
SUCTION
suction pump.
KEYS
KEYS
KEYS
and
KEYS
KEYS
temperature of the handpiece. This enables
temperatures from 150 to 450°C (300 to 840°F)
to be selected.
The selected temperatures are reference values
which may change depending on the distance
between the heating element and the nozzle.
The display shows the actual air temperature
when the unit is working measured at a distance
of 10mm from the nozzle.
SELECT
SELECT. It allows the access to the SETUP
SELECT
SELECT
SELECT
mode of the station.
- CONTROLS:
AIR FLOW
This enables the air flow to be set on a scale
from 1 (corresponding to the lowest setting of
4 l/min) to 10 (corresponding to the highest of
12 l/min).
Heating element ON-OFF switch
. Decrease or increase the
- PEDAL:
Hot air is produced when it is held down.
Releasing it the heater is disconnected,
though the turbine continues to operate until
the air temperature falls below 100°C (212°F)
Pedal
Ref. 0964551
- VACUUM SELECTOR:
Two vacuum inlets avalaible for tripods and
extractors, being active the one that coincides
with the arrow.
3
Air flow
regulation
Heater inlet

Publicidad

loading