Ecodryer Blade Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
Trouble shooting & Precautions before installation
If you discover the following circumstance, please inspect and handle as following:
Problem
No air blows when
stretch hands into
U-shaped groove
Machine works long
time after hands
drawn out, finally
stop
No hot wind
Airflow is too low
Status Indicator
flashes
Do not install in the following types of location, otherwise this may cause malfunction:
Locations where the temperature can exceed -10 C or 40 C.
Locations where the unit may come into direct contact with water.
Locations where the unit is under direct or strong sunlight.
Locations where there is a lot of condensation.
Locations where corrosive, neutral, or reductive gases are present.
Places lower than -20m or higher than 2000m above sea level.
Installation location
Install the unit where it will be easy to use, as shown in the figure.
If the unit is installed too low, water may get on it when the floor is being cleaned. (The bottom of the
unit must be at least 150 mm higher than the floor or any objects under it.)
The left side of the unit must be at least 150 mm away from any walls, because the side door to
access to drainage route is located on the left.
Ensure there are no mirrors or walls near the right side, as drops of water may splatter to the right
when drying hands. (Recommended distance is at least 100 mm.)
Avoid locations where people or doors might bump to the unit.
Choose a completely flat surface on the wall to install the unit.
Installation Base
If your space is limited and the condition of wall is not strong enough,
you can purchase an installation base to install this unit.
Check
Do the display indicators
lights up?
Is the power switch on?
Are you putting your hands
all the way in?
Any dirt or foreign body
on sensor?
There is a Built-in heater
in the unit. Any dirt on
heating sensor?
Fuse inside terminal box
blown?
Is the speed button on
low level?
Is the reaction plate
activated for a long
time
Action
Turn the ground-fault circuit breaker on.
Turn the power switch on.
Put your hands in again.
Switch off the power button, and then remove
dirt or foreign body on sensor after the power
light off When finished, switch on power
button.
Is the ambient temperature higher than 22°C?
Switch off power, remove front cover. There is
a terminal box inside. Take down the cover of
terminal box. Check the fuse inside box which
is blown or not.
Put speed button on the high level.
Firstly turn off the machine, put a screen that
block 3-way sensor completely in the middle of
the sensor. Then turn on the machine over 3s,
remove the screen. Start to detect 1-3 sensors, let
it respectively and automatically flash, try to work
properly after completion of the focus.
Expansion screw drilling
Fixing screw
can
The mounting screw holes
Machine hanging hole
Wall screw into position
Fixing screw