14.3.3
Overheating Protection Facility
14.3.4
Automatic shutdown protection
14.3.5
Rating plate
caso Master E4 Slide
The appliance is equipped with an overheating protection facility.
If the temperature of the appliance exceeds the critical limit the
appropriate error message is displayed and an acoustic signal
sounds. For safety reasons the appliance shuts off further power
supply. After the cooling-down phase the appliance can be
switched on again.
► Do not place any empty cookware on the cooking area.
Heating an empty pot or pan activates the overheating
protection and the device turns off automatically.
The device is equipped with an auto shut down safety protection
function. If ever you forgot to turn off your hotplate, it shuts down
automatically. The default working times for various power levels
are:
Power level
1~3
4~6
7~9
The rating plate with the connection and performance data can
be founded on the back of the device.
Design and Function
automatic shutdown after
8 hours
4 hours
2 hours
58