START IN OPENING
This menu permits to select the functions of start during the
opening phase.
PAUS the command START stop the gate and goes into in
ChiU
no
START IN CLOSING
This menu permits to select the functions of start during the
closing phase.
StoP
APEr
START IN PAUSE
This menu permits to select the functions of the command
start during the standstill.
ChiU
no
PEDESTRIAN START IN OPENING
This menu permits to select the functions of the command of
START P . during the opening phase.
PAUS the command PEDESTRIAN START stops the gate and
ChiU
no
AUTOMATIC CLOSING
Permits the selection between the semiautomatic or automatic functio-
ning. By the semiautomatic functioning the command of START or PEDE-
STRIAN START opens the gate, when the opening is complete the gate
remains still until the successive command of opening, which will reclose
it. On the other hand, it stops automatically and remains in pause phase
for the set time, then it closes again through the set closing time.
no
the automatic reclosing is not available, the gate is semiautomatic.
0.5"÷20' the reclosing is available, the standstill time is set from 0.5" to 20'.
IMPORTANT: If the automatic reclosing is not available, is necessary to enable
the start command in pause(menu St.PA)
22
PAUSE.
the command START close the gate.
the command START is not available.
the command START stop the gate.
the command START open the gate
the command START closes the gate.
the command START is not available. This function
cannot be selected until the automatic closing has
been activated (menu Ch.AU).
goes in pause.
the command PEDESTRIAN START closes the gate.
the command PEDESTRIAN START is not available.