Gas range installation
1> Leave at least 80 to 85cm between the top of the gas range and any
cabinet or range hood install above prepared to be installed built in.
2cm
2>Leave at least
in the back and each side of the gas range to allow
the heat to get out.
2cm
80 to 85cm
3>Make sure to not blok the oven gas exit, including the funnel or the gas vents,
when you install the oven.
4> Metal bracket should be fixed well,to ensure the heat of back cover can go out smooth.
Gas installation
1>This range was designed for use with LP gas
2> Always use a pressure regulator exclusive for your gas range. The lack of
pressure regulator might cause excess of pressure and leak of gas. Always
check for the validity of the pressure regulator. Hose and regulartor should
be replaced every 5 years. Technical specificaltion of the pressure regulator.
·Pressure: 200mm C.A.
·Max. consumption: 2kg/h
3> Always use a PVC hose to work from-20
to 100
. Be sure that hose:
O
O
C
C
·does not have joints.
·does not go on the back of the gas range neither close to the hot air exits.
·Its less then 125cm long.
4> If possible, install the gas cylinder outside the kitchen, in a place protected
and with air flow.
5> Use a ½ metallice hose to connect to the gas range.
6> Only use a plastic hose when this one does not go on the back of the gas range.
Hose installation
1> Place the metal clamp on the hose end.
2> Connect the hose to the oven inlet and tighten the clamp.
3> Place the other clamp on the oppsite hose end and connect it to the pressure regulator,
Tighten the clamp.
4>Bolt the pressure regulator to the gas cylinder carefully.
5> After the installation, check if there is any gas leak, using soap or liquid detergent foam.