BONFIGLIOLI Vectron Agile AGL202 Guia De Inicio Rapido página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

D
Wiring of control cables
Danger!
Switch off power supply before connecting or disconnecting terminals.
1.5 mm
max.
2.5 mm
Operating via control signals
D1
X13
X12
n
Start
E
X11
1
3 4 5
Start cw:
start clockwise
Start ccw:
start anticlockwise
VDC out:
voltage outputs
E:
Enable
Start drive via control signals:
After Setup switch on start signals on X11.4 (start
clockwise) or X11.5 (start anticlockwise). The drive is
accelerated to 3.50 Hz (default value of P418).
Before commissioning, all covers must be mounted on the frequency inverter.
In case of errors refer to section "Error messages and warnings".
In case of wrong direction of rotation exchange two motor phases (e.g. U and V).
Note
For the default functions of all control terminals refer to section "Functions of control terminals".
05/2013
Use shielded control cables.
Connect the conductor shielding of the control cables to ground potential by
means of the shielding clamp.
Connect the conductor shielding to ground potential on both sides of the
cable. Analog cables must be grounded only on the inverter side.
The control cable must be separated from the motor cable and mains cable
(not in the same cable duct).
X13
X12
2
X11
2
2 3
4
> 4k7
3
Operating via Operator panel
D2
X13
X12
E
X11
1
E: Enable
Start drive via key of operator panel
After Setup select function Motorpoti (menu Local/
Poti F, refer to section „Menus and functions").
Press RUN.
The drive is accelerated to 3.50Hz
(default value of P. 418).
Press the arrow keys to the speed.
35
3
3
Quick Start Guide
Agile

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vectron agile agl402

Tabla de contenido