Technical Data Of Control Terminals - BONFIGLIOLI Vectron Agile AGL202 Guia De Inicio Rapido

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Technical data of control terminals

Voltage
X11.1
DC 24 V, Imax =100 mA. Appropriate GND: X11.2.
X13.4
DC 10 V, Imax =2.3 mA (dependent on level of DC 24 V voltage input), Imax = 8.2 mA
outputs
Input for external voltage supply. Connect the ground potential of the external voltage
X13.1
supply to X13.2 (GND).
Input voltage range
Voltage
Rated input current
inputs
Peak inrush current
External fuse
Safety
X11.3
Signal levels
Digital
X13.3
U
enable
max
Input Resistance
inputs
Response time
X11.4
Signal levels
X11.5
Digital
X12.1
U
max
inputs
X12.2
Input resistance
Response time
PLC compatibile
X11.6
X12.3
X12.4
X13.5
U
out
Digital
I
max
outputs
X11.6
Analog
X12.3
X12.4
inputs
X11.6
Default: digital input. —► Refer to table row "Digital inputs".
Digital
Can be configured as digital output by means of P558.
input/
Output:
output
Overload- and short circuit-proof, overvoltage- protected.
Multifunction
Digital/
X12.3
Default: analog voltage input. Can be configured as analog current input or digital input by
means of P452.
analog
Voltage input
input
Current input
Digital input
Digital/
X12.4
Default: digital. Can be configured as analog input MFI2A by means of P562.
analog
Voltage input
input
Current input
Digital input
Digital/
X13.6
Default: analog. Can be configured as digital output, analog output, frequency output or pulse
train output by means of P550.
analog/
Analog signal: pulse width modulated, f
frequency/
Digital output:
pulse train
output
Overload- and short circuit-proof, overvoltage- protected.
Relay
X10
Maximum contact load:
make contact: AC 5A/ 240V, DC 5A (ohmic)/ 24V,
output
break contact: AC 3A/ 240V, DC 1A (ohmic)/ 24V
Caution!
The digital inputs and the DC 24 V input can withstand external voltage up to DC 30 V. Avoid higher voltage levels.
The temperature monitoring must be sufficient insulated towards the motor winding.
Agile
Quick Start Guide
DC 24 V ± 10%
Max. 1.0 A (typical 0.45 A)
Typical < 15 A (max. 100 μs)
Via standard fuse element for rated current, characteristic: slow
Safety extra low voltage (SELV) according to EN 61800-5-1
Low DC 0 ... 3 V, High DC 12 ... 30 V
DC 30 V (10 mA at DC 24 V)
1.8 kΩ
STO is activated 10 ms after triggering.
PNP input
NPN input
DC 30 V (6 mA at DC 24 V)
3.9 kΩ
2 ms
Digital input/ output
Multifunction
Multifunction
DC 22 V (DC 15 ... 30 V)
100 mA (I
max
Overload- and short circuit-proof, overvoltage- protected.
Digital input/ output
Multifunction
Multifunction
U
DC 22 V (DC 15 ... 30 V)
out
I
100 mA (I
max
DC 0...10 V (R
DC 0...20 mA (R
DC 0...10 V (R
DC 0...20 mA (R
U
DC 22 V (DC 15 ... 30 V)
out
I
100 mA (Imax is reduced if further control outputs are used.)
max
High ≥ DC 10 V
High ≤ DC 5 V
is reduced if further control outputs are used.)
is reduced if further control outputs are used.)
max
= 78 kΩ)
i
= 250 Ω)
i
Refer to table row "Digital inputs".
= 78 kΩ)
i
= 250 Ω)
i
Refer to table row "Digital inputs".
= 115 Hz. Frequency signal: f
PWM
50
Switch-over PNP/ NPN
X11.4
P559
X12.3
P452
X11.5
X12.4
P562
X12.1
X12.2
X11.6
Resolution 10 Bit
R
: input
i
resistance
Resolution 9 Bit
Resolution 10 Bit
R
: input
i
resistance
Resolution 9 Bit
= 150 kHz.
max
05/2013

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vectron agile agl402

Tabla de contenido