ELKO EP, s.r.o.
Palackého 493
769 01 Holešov, Všetuly
Czech Republic
Tel.: +420 573 514 211
e-mail: elko@elkoep.com
www.elkoep.com
Made in Czech Republic
02-26/2017 Rev.: 0
Characteristics
- multifunction relay designed for installation into a wiring box or under wall-switch
in an existing electrical installation
- advantageous and fast solution for exchanging standard wall-switch for a switch
controlled by time or for an impulse relay controlled by a button
- time scale 0.1 s - 10 days divided into 10 ranges:
(0.1 s - 1 s / 1 s - 10 s / 0.1 min - 1 min / 1 min - 10 min / 0.1 hrs - 1 hrs / 1 hrs -
10 hrs / 0.1 day - 1 day / 1 day - 10 days / only ON / only OFF)
SMR-K
- 3-wire connection, works without the connection of a neutral conductor
- power output: 10 - 160 VA
- for fl awless function of the product is necessary the presence of a load R, L or C
between input S and neutral wire
SMR-T
- 3-wire connection, works without the connection of a neutral conductor
- power output: 10 - 160 VA
- between input S and neutral wire is possible connect any load R, L, or C - that is not
necessary (unlike SMR-K)
SMR-H
- 4-wire connection
- power output: 0 - 200 VA
SMR-B
- 4-wire connection
- 10 functions
- output contact 1x 16 A / 4000 VA, 250 V AC1
- enables switching of fl uorescent lights and also energy saving lights
- suitable for switching loads greater than SMR-K, SMR-T, SMR-H, for example pulse
relay, stair automatic switch, switching of ladder radiators in bathrooms
- independent galvanically separated input AC/DC 5 - 250 V, for example for control
from a security system
Description
SMR-H
1
2
3
4
5
6
cos φ ≥ 0.95
Type of load
AC1
Mat. contacts AgSnO
,
2
contact 16A
250V / 16A
Type of load
AC13
Mat. contacts AgSnO
,
2
contact 16A
x
SMR-B
10
2
9
3
8
8
7
7
M
M
AC2
AC3
uncompensated
250V / 5A
250V / 3A
230V / 3A (690VA)
K
AC14
AC15
250V / 6A
250V / 6A
Connection
N
L
Typical wiring of SMR-K
- timer for fan
N
L
V
L
S
SMR-H
Typical wiring of SMR-H
- timer for lamp
Note: SMR-K, SMR-T, SMR-H are not intended for switching capacity load (energy sav-
ing bulbs and LED lights with capacity power etc.), these products are only intended for
switching resistive and inductive loads (incandescent bulbs, fans, etc.). SMR-B with relay
output is intended to other types of load. Using this output it is possible to switch the
load of R, L or C-values listed in the load table.
4
1
5
6
AC5a
AC5a
compensated
230V / 3A (690VA)
to max. input C=14uF
M
DC3
DC1
24V / 3A
24V / 10A
1 / 2
SMR-K, SMR-T,
SMR-H, SMR-B
Super-multifunction relay
V
L
S
V
SMR-K
Fan controlling depending
on the lighting
N
V
L
S
N
SMR-H
Fan control depending
on the lighting
1. Output indication
2. Rought time setting
3. Fine time setting
4. Function setting
5. Neutral conductor
6. Switch (button)
7. Phase conductor
8. Output to appliance
9. Exchangeable fuse
10. Galvanically separated control input
5 - 250 V AC/DC
HAL.230V
AC5b
AC6a
1000W
x
M
DC5
DC12
24V / 2A
24V / 6A
EN
L
S
SMR-T
N
S
L
V
SMR-B
IN-
IN+
Input for external control
voltage AC/DC 5 - 250 V
AC7b
AC12
250V / 3A
x
DC13
DC14
24V / 2A
x